» Articles » PMID: 31856135

Evaluation of Open Reduction and Internal Fixation of Mandibular Condyle Fracture by Intraoperative Cone-Beam Computed Tomography in a Hybrid Operating Room

Overview
Date 2019 Dec 20
PMID 31856135
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

Condylar fractures are the most common fractures of the mandible, and treatment of mandibular condylar fractures by maxillofacial surgeons is a very important procedure. However, the surgical approaches have anatomical limitations. Therefore, it is difficult to evaluate the reduction achieved in open reduction and internal fixation because of the uncertainty in securing a sufficient operative field. As a potential solution, the authors evaluated the benefits of intraoperative cone-beam computed tomography (CBCT) with high image quality performed in a hybrid operating room. Intraoperative CBCT is easy to perform in a hybrid operating room, and it is possible to quickly evaluate high-quality CT images, including 3D images. Because the state of reduction of mandibular condylar fractures also affects the prognosis of treatment, more precise reduction and fixation should improve prognoses. The use of CBCT in a hybrid operating room also avoids re-operation, and patients benefit from minimum invasive surgery. Intraoperative CBCT is a very useful strategy for evaluation of mandibular condylar fracture surgical treatment.

Citing Articles

Condyle Fracture Fixed with Custom-Made Titanium Mesh and a Miniplate: A Case Report.

Kawai T, Kawamata S, Suzuki S, Ishikawa Y, Ikeda Y, Yasuge E Am J Case Rep. 2023; 24:e940681.

PMID: 37376731 PMC: 10316717. DOI: 10.12659/AJCR.940681.


Use of Intraoperative C-Arm Fluoroscopy in Open Reduction and Internal Fixation of Mandibular Condyle Fracture - A Case Report.

Kumar J, Kumar S, Kapoor S, Thakker R, Bhatnagar A, Singh M Ann Maxillofac Surg. 2022; 12(1):114-116.

PMID: 36199452 PMC: 9527832. DOI: 10.4103/ams.ams_40_22.


Subcutaneous Emphysema Related to Dental Treatment: A Case Series.

Shimizu R, Sukegawa S, Sukegawa Y, Hasegawa K, Ono S, Fujimura A Healthcare (Basel). 2022; 10(2).

PMID: 35206904 PMC: 8872011. DOI: 10.3390/healthcare10020290.

References
1.
Pohlenz P, Blessmann M, Blake F, Heinrich S, Schmelzle R, Heiland M . Clinical indications and perspectives for intraoperative cone-beam computed tomography in oral and maxillofacial surgery. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2007; 103(3):412-7. DOI: 10.1016/j.tripleo.2006.05.008. View

2.
Richter P, Gebhard F, Dehner C, Scola A . Accuracy of computer-assisted iliosacral screw placement using a hybrid operating room. Injury. 2015; 47(2):402-7. DOI: 10.1016/j.injury.2015.11.023. View

3.
Pohlenz P, Blessmann M, Blake F, Gbara A, Schmelzle R, Heiland M . Major mandibular surgical procedures as an indication for intraoperative imaging. J Oral Maxillofac Surg. 2008; 66(2):324-9. DOI: 10.1016/j.joms.2007.03.032. View

4.
Hoelzle F, Klein M, Schwerdtner O, Lueth T, Albrecht J, Hosten N . Intraoperative computed tomography with the mobile CT Tomoscan M during surgical treatment of orbital fractures. Int J Oral Maxillofac Surg. 2001; 30(1):26-31. DOI: 10.1054/ijom.2000.0014. View

5.
Kaneko T, Davidson M . Use of the hybrid operating room in cardiovascular medicine. Circulation. 2014; 130(11):910-7. DOI: 10.1161/CIRCULATIONAHA.114.006510. View