Automatic Detection of Reverse-triggering Related Asynchronies During Mechanical Ventilation in ARDS Patients Using Flow and Pressure Signals

Abstract

Asynchrony due to reverse-triggering (RT) may appear in ARDS patients. The objective of this study is to validate an algorithm developed to detect these alterations in patient-ventilator interaction. We developed an algorithm that uses flow and airway pressure signals to classify breaths as normal, RT with or without breath stacking (BS) and patient initiated double-triggering (DT). The diagnostic performance of the algorithm was validated using two datasets of breaths, that are classified as stated above. The first dataset classification was based on visual inspection of esophageal pressure (Pes) signal from 699 breaths recorded from 11 ARDS patients. The other classification was obtained by vote of a group of 7 experts (2 physicians and 5 respiratory therapists, who were trained in ICU), who evaluated 1881 breaths gathered from recordings from 99 subjects. Experts used airway pressure and flow signals for breaths classification. The RT with or without BS represented 19% and 37% of breaths in Pes dataset while their frequency in the expert's dataset were 3% and 12%, respectively. The DT was very infrequent in both datasets. Algorithm classification accuracy was 0.92 (95% CI 0.89-0.94, P < 0.001) and 0.96 (95% CI 0.95-0.97, P < 0.001), in comparison with Pes and experts' opinion. Kappa statistics were 0.86 and 0.84, respectively. The algorithm precision, sensitivity and specificity for individual asynchronies were excellent. The algorithm yields an excellent accuracy for detecting clinically relevant asynchronies related to RT.

Citing Articles

Closing the Gap in Patient-Ventilator Discordance Recognition.

Liendo A, Mireles-Cabodevila E Respir Care. 2024; 69(2):272-274.

PMID: 38267228 PMC: 10898463. DOI: 10.4187/respcare.11825.


Reverse Triggered Breath during Pressure Support Ventilation and Neurally Adjusted Ventilatory Assist at Increasing Propofol Infusion.

Longhini F, Simonte R, Vaschetto R, Navalesi P, Cammarota G J Clin Med. 2023; 12(14).

PMID: 37510970 PMC: 10381884. DOI: 10.3390/jcm12144857.


The oesophageal balloon for respiratory monitoring in ventilated patients: updated clinical review and practical aspects.

Jonkman A, Telias I, Spinelli E, Akoumianaki E, Piquilloud L Eur Respir Rev. 2023; 32(168).

PMID: 37197768 PMC: 10189643. DOI: 10.1183/16000617.0186-2022.


Reverse Triggering: An Introduction to Diagnosis, Management, and Pharmacologic Implications.

Murray B, Sikora A, Mock J, Devlin T, Keats K, Powell R Front Pharmacol. 2022; 13:879011.

PMID: 35814233 PMC: 9256988. DOI: 10.3389/fphar.2022.879011.


What is new in respiratory monitoring?.

Karbing D, Leonhardt S, Perchiazzi G, Bates J J Clin Monit Comput. 2022; 36(3):599-607.

PMID: 35552970 PMC: 9103600. DOI: 10.1007/s10877-022-00876-4.