Flow diverter devices have gained wide acceptance for the treatment of unruptured intracranial aneurysms. Most studies are based on the treatment of large aneurysms harboring on the carotid syphon. However, during the last years the "off-label" use of these stents has widely grown up even if not supported by randomized studies. This review examines the relevant literature concerning "off-label" indications for flow diverter devices, such as for distal aneurysms, bifurcation aneurysms, small aneurysms, recurrent aneurysms, and direct carotid cavernous fistulas.

Citing Articles

Endovascular treatment of intracranial aneurysms with silk vista baby flow diverter: A systematic review and meta-analysis.

Hajikarimloo B, Mohammadzadeh I, Tos S, Hashemi R, Habibi M, Hasanzade A Neuroradiol J. 2025; :19714009251324324.

PMID: 40016880 PMC: 11869223. DOI: 10.1177/19714009251324324.


Flow Diversion for Endovascular Treatment of Intracranial Aneurysms: Past, Present, and Future Directions.

Gaub M, Murtha G, Lafuente M, Webb M, Luo A, Birnbaum L J Clin Med. 2024; 13(14).

PMID: 39064207 PMC: 11278297. DOI: 10.3390/jcm13144167.


Y Stent-Assisted Coiling Technique for Bifurcation Aneurysms Using Double Neuroform® Stent: a Large Restrospective Series.

Caamano I, Remollo S, Terceno M, Blanco A, Bashir S, Castano C Clin Neuroradiol. 2024; 34(4):919-928.

PMID: 39023542 DOI: 10.1007/s00062-024-01437-9.


The Safety and Efficacy of Leo Stents with Coiling or Alone for Anterior Cerebral Artery Aneurysms.

Duan Y, Shen J, Qin X, Xu B, Mao R, Li J Curr Neurovasc Res. 2024; 20(5):560-567.

PMID: 39004959 DOI: 10.2174/0115672026271147231130111233.


Endovascular treatment of direct carotid cavernous fistula resulting from rupture of intracavernous carotid aneurysm: A case report.

Ouyang G, Zheng K, Luo K, Qiao M, Zhu Y, Pan D World J Clin Cases. 2024; 12(11):1940-1946.

PMID: 38660547 PMC: 11036523. DOI: 10.12998/wjcc.v12.i11.1940.


References
1.
Ravindran K, Enriquez-Marulanda A, Kan P, Renieri L, Limbucci N, Mangiafico S . Use of Flow Diversion for the Treatment of Distal Circulation Aneurysms: A Multicohort Study. World Neurosurg. 2018; 118:e825-e833. DOI: 10.1016/j.wneu.2018.07.062. View

2.
Daou B, Starke R, Chalouhi N, Tjoumakaris S, Hasan D, Khoury J . Pipeline Embolization Device in the Treatment of Recurrent Previously Stented Cerebral Aneurysms. AJNR Am J Neuroradiol. 2015; 37(5):849-55. PMC: 7960319. DOI: 10.3174/ajnr.A4613. View

3.
Pistocchi S, Blanc R, Bartolini B, Piotin M . Flow diverters at and beyond the level of the circle of willis for the treatment of intracranial aneurysms. Stroke. 2012; 43(4):1032-8. DOI: 10.1161/STROKEAHA.111.636019. View

4.
Lenz-Habijan T, Bhogal P, Peters M, Bufe A, Martinez Moreno R, Bannewitz C . Hydrophilic Stent Coating Inhibits Platelet Adhesion on Stent Surfaces: Initial Results In Vitro. Cardiovasc Intervent Radiol. 2018; 41(11):1779-1785. PMC: 6182755. DOI: 10.1007/s00270-018-2036-7. View

5.
Chalouhi N, Chitale R, Starke R, Jabbour P, Tjoumakaris S, Dumont A . Treatment of recurrent intracranial aneurysms with the Pipeline Embolization Device. J Neurointerv Surg. 2013; 6(1):19-23. DOI: 10.1136/neurintsurg-2012-010612. View