» Articles » PMID: 31821876

Cytomorphological Assessment of the Lid Margin in Relation to Symptoms, Contact Lens Wear and Lid Wiper Epitheliopathy

Overview
Journal Ocul Surf
Specialty Ophthalmology
Date 2019 Dec 11
PMID 31821876
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: Lid wiper epitheliopathy (LWE) is insufficiently understood from a cytological perspective. This study explored the relationship between lid margin cytomorphology, LWE, contact lens wear, and lens-related symptoms.

Methods: Habitual, symptomatic (n = 20) and asymptomatic (n = 20) soft, rigid gas permeable (n = 18) and non-contact lens wearers (n = 19) were enrolled. LWE was graded using lissamine green and the Korb scale. Subjective symptoms were assessed using the Ocular Surface Disease Index and the Contact Lens Dryness Evaluation Questionnaire. Impression cytology samples obtained from the central upper and lower lid margins of both eyes stained histologically to highlight keratinization and imaged using high-resolution microscopy. A masked investigator digitally delimited and measured the average sagittal width of the lid wiper conjunctiva and mucocutaneous junction using ImageJ.

Results: The upper lid wiper conjunctiva measured 424 ± 171 μm, 404 ± 75, 667 ± 219 and 266 ± 64 in asymptomatic soft, symptomatic soft, rigid and non-contact lens wearers, respectively. The corresponding lower lid wiper conjunctivae measured 141 ± 57 μm, 232 ± 150, 519 ± 212 and 225 ± 102, which was significantly narrower than that of the upper eyelid in most cases (p < 0.05). Symptoms were not associated with lid margin changes; however, rigid lens wear and clinical LWE were associated with histologically enlarged lid wiper conjunctival areas and increased keratinization.

Conclusion: A novel, exploratory account of histological measures of LWE and cytomorphological change associated with contact lens wear suggests mechanical or frictional cellular insult is occurring at the lid wiper conjunctiva.

Citing Articles

Effect of lid-wiper epitheliopathy on the corneal epithelial thickness distribution: a novel semiautomatic quantitative method.

Ye J, Lin M, Chen X, Yang Y, Lin J, Ma D BMC Ophthalmol. 2025; 25(1):113.

PMID: 40055681 PMC: 11887165. DOI: 10.1186/s12886-025-03918-y.


Successful Management of a Keratoconus Patient With Rarely Used Large-Diameter Corneal RGP Contact Lenses: A Case Report.

Almaweri A Cureus. 2025; 17(1):e77801.

PMID: 39991378 PMC: 11843064. DOI: 10.7759/cureus.77801.


Eyelid cleaning: Methods, tools, and clinical applications.

Zhang L, Wang J, Gao Y Indian J Ophthalmol. 2023; 71(12):3607-3614.

PMID: 37991291 PMC: 10788755. DOI: 10.4103/IJO.IJO_1457_23.


Impact of Improper Approach to Identify Lid Wiper Epitheliopathy (LWE).

Lievens C, Norgett Y, Briggs N, Allen P, Vianya-Estopa M Clin Ophthalmol. 2020; 14:3039-3047.

PMID: 33116355 PMC: 7547802. DOI: 10.2147/OPTH.S273524.