» Articles » PMID: 31799029

Retina Phantom for the Evaluation of Optical Coherence Tomography Angiography Based on Microfluidic Channels

Overview
Specialty Radiology
Date 2019 Dec 5
PMID 31799029
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

Optical coherence tomography (OCT) angiography (OCTA) has been actively studied as a noninvasive imaging technology to generate retinal blood vessel network maps for the diagnoses of retinal diseases. Given that the uses of OCT and OCTA have increased in the field of ophthalmology, it is necessary to develop retinal phantoms for clinical OCT for product development, performance evaluation, calibration, certification, medical device licensing, and production processes. We developed a retinal layer-mimicking phantom with microfluidic channels based on microfluidic fabrication technology using polydimethylsiloxane (PDMS) and titanium dioxide (TiO) powder. We implemented superficial and deep retinal vessels using microfluidic channels. In addition, multilayered thin films were synthesized with multiple spin-coating processes that comprised layers that corresponded to the retinal layers, including the ganglion cell layer (GCL), inner plexiform layer (IPL), and inner nuclear layer (INL). The phantom was formed by merging the multilayered thin film, and microfluidic channels were assembled with an optical lens, water chamber, and an aluminum tube case. Finally, we obtained cross-sectional OCT images and OCTA images of the retinal phantom using lab-made ophthalmic OCT. From the cross-sectional OCT image, we could compare each of the layer thicknesses of the phantom with the corresponding layer thicknesses of the human retina. In addition, we obtained OCTA images with injections of intralipid solutions. It is shown that this phantom will be able to be potentially used as a convenient tool to evaluate and standardize the quality and accuracy of OCT and OCTA images.

Citing Articles

Compact Linear Flow Phantom Model for Retinal Blood-Flow Evaluation.

Raghavendra A, Elhusseiny A, Agrawal A, Liu Z, Hammer D, Saeedi O Diagnostics (Basel). 2024; 14(15).

PMID: 39125491 PMC: 11311845. DOI: 10.3390/diagnostics14151615.


Rapid prototyping of a retinal multivascular network phantom for optical retinal vascular imaging equipment evaluation.

Zhao X, Liu W, Hu Z, Duan L, Zhang X, Li F Biomed Opt Express. 2024; 15(7):4253-4263.

PMID: 39022546 PMC: 11249693. DOI: 10.1364/BOE.523115.


Durable 3D murine ex vivo retina glaucoma models for optical coherence tomography.

Barroso A, Ketelhut S, Nettels-Hackert G, Heiduschka P, Amor R, Naranjo V Biomed Opt Express. 2023; 14(9):4421-4438.

PMID: 37791268 PMC: 10545187. DOI: 10.1364/BOE.494271.


In vivo imaging of renal microvasculature in a murine ischemia-reperfusion injury model using optical coherence tomography angiography.

Lee B, Kang W, Oh S, Cho S, Shin I, Oh E Sci Rep. 2023; 13(1):6396.

PMID: 37076541 PMC: 10115874. DOI: 10.1038/s41598-023-33295-9.


Polydimethylsiloxane tissue-mimicking phantoms with tunable optical properties.

Goldfain A, Lemaillet P, Allen D, Briggman K, Hwang J J Biomed Opt. 2021; 27(7).

PMID: 34796707 PMC: 8601433. DOI: 10.1117/1.JBO.27.7.074706.


References
1.
Lopez-Saez M, Ordoqui E, Tornero P, Baeza A, Sainza T, Zubeldia J . Fluorescein-induced allergic reaction. Ann Allergy Asthma Immunol. 1998; 81(5):428-30. DOI: 10.1016/S1081-1206(10)63140-7. View

2.
de Bruin D, Bremmer R, Kodach V, de Kinkelder R, van Marle J, van Leeuwen T . Optical phantoms of varying geometry based on thin building blocks with controlled optical properties. J Biomed Opt. 2010; 15(2):025001. DOI: 10.1117/1.3369003. View

3.
Dalod A, Grendal O, Blichfeld A, Furtula V, Perez J, Henriksen L . Structure and Optical Properties of Titania-PDMS Hybrid Nanocomposites Prepared by In Situ Non-Aqueous Synthesis. Nanomaterials (Basel). 2017; 7(12). PMC: 5746949. DOI: 10.3390/nano7120460. View

4.
Lozzi A, Agrawal A, Boretsky A, Welle C, Hammer D . Image quality metrics for optical coherence angiography. Biomed Opt Express. 2015; 6(7):2435-47. PMC: 4505700. DOI: 10.1364/BOE.6.002435. View

5.
de Kinkelder R, de Bruin D, Verbraak F, van Leeuwen T, Faber D . Comparison of retinal nerve fiber layer thickness measurements by spectral-domain optical coherence tomography systems using a phantom eye model. J Biophotonics. 2012; 6(4):314-20. DOI: 10.1002/jbio.201200018. View