» Articles » PMID: 31790441

Hydrogel Based Protein Biochip for Parallel Detection of Biomarkers for Diagnosis of a Systemic Inflammatory Response Syndrome (SIRS) in Human Serum

Overview
Journal PLoS One
Date 2019 Dec 3
PMID 31790441
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

The Systemic Inflammatory Response Syndrome (SIRS), a sepsis related inflammatory state, is a self-defense mechanism against specific and nonspecific stimuli. The six most extensively studied inflammatory biomarkers for the clinical diagnosis of SIRS are interleukin 4 (hIL-4), interleukin 6 (hIL-6), interleukin 10 (hIL-10), tumor necrosis factor alpha (hTNF-α), interferon gamma (hIFN-γ) and procalcitonin (hPCT). These biomarkers are naturally present (but usually only at low concentration) in SIRS infected patients [1, 2] and thus the development of a highly sensitive detection method is of major clinical interest. However, the existing analytical techniques are lacking in required analytical sensitivity and parallel determination of these biomarkers. We developed a fast, easy and cost-efficient protein microarray biochip where the capture molecules are attached on hydrogel spots, enabling SIRS diagnosis by parallel detection of these six clinically relevant biomarkers with a sample volume of 25 μl. With our hydrogel based protein microarray biochip we achieved a limit of detection for hIL-4 of 75.2 pg/ml, for hIL-6 of 45.1 pg/ml, for hIL-10 of 71.5 pg/ml, for hTNF-α of 56.7 pg/ml, for IFN-γ of 46.4 pg/ml and for hPCT of 1.1 ng/ml in spiked human serum demonstrating sufficient sensitivity for clinical usage. Additionally, we demonstrated successful detection of two relevant SIRS biomarkers in clinical patient samples with a turnaround time of the complete analysis from sample-to-answer in less than 200 minutes.

Citing Articles

Macroporous Polymer Monoliths in Thin Layer Format.

Korzhikova-Vlakh E, Antipchik M, Tennikova T Polymers (Basel). 2021; 13(7).

PMID: 33801786 PMC: 8037505. DOI: 10.3390/polym13071059.

References
1.
Gagni P, Romanato A, Bergamaschi G, Bettotti P, Vanna R, Piotto C . A self-assembling peptide hydrogel for ultrarapid 3D bioassays. Nanoscale Adv. 2022; 1(2):490-497. PMC: 9473263. DOI: 10.1039/c8na00158h. View

2.
Wilson D, Nock S . Functional protein microarrays. Curr Opin Chem Biol. 2002; 6(1):81-5. DOI: 10.1016/s1367-5931(01)00281-2. View

3.
Lvovschi V, Arnaud L, Parizot C, Freund Y, Juillien G, Ghillani-Dalbin P . Cytokine profiles in sepsis have limited relevance for stratifying patients in the emergency department: a prospective observational study. PLoS One. 2012; 6(12):e28870. PMC: 3248412. DOI: 10.1371/journal.pone.0028870. View

4.
JACKSON T, Ekins R . Theoretical limitations on immunoassay sensitivity. Current practice and potential advantages of fluorescent Eu3+ chelates as non-radioisotopic tracers. J Immunol Methods. 1986; 87(1):13-20. DOI: 10.1016/0022-1759(86)90338-8. View

5.
Rosenberg-Hasson Y, Hansmann L, Liedtke M, Herschmann I, Maecker H . Effects of serum and plasma matrices on multiplex immunoassays. Immunol Res. 2014; 58(2-3):224-33. PMC: 4332596. DOI: 10.1007/s12026-014-8491-6. View