Glenohumeral Joint Capsular Tissue Tension Loading Correlates Moderately with Shear Wave Elastography: a Cadaveric Investigation

Overview
Journal Ultrasonography
Date 2019 Dec 3
PMID 31786904
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: The purpose of this study was to investigate changes in the mechanical properties of capsular tissue using shear wave elastography (SWE) and a durometer under various tensile loads, and to explore the reliability and correlation of SWE and durometer measurements to evaluate whether SWE technology could be used to assess tissue changes during capsule tensile loading.

Methods: The inferior glenohumeral joint capsule was harvested from 10 fresh human cadaveric specimens. Tensile loading was applied to the capsular tissue using 1-, 3-, 5-, and 8-kg weights. Blinded investigators measured tissue stiffness and hardness during loading using SWE and a durometer, respectively. Intraobserver reliability was established for SWE and durometer measurements using intraclass correlation coefficients (ICCs). The Pearson product-moment correlation was used to assess the associations between SWE and durometer measurements.

Results: The ICC3,5 for durometer measurements was 0.90 (95% confidence interval [CI], 0.79 to 0.96; P<0.001) and 0.95 (95% CI, 0.88 to 0.98; P<0.001) for SWE measurements. The Pearson correlation coefficient values for 1-, 3-, and 5-kg weights were 0.56 (P=0.095), 0.36 (P=0.313), and -0.56 (P=0.089), respectively. When the 1- and 3-kg weights were combined, the ICC3,5 was 0.72 (P<0.001), and it was 0.62 (P<0.001) when the 1-, 3-, and 5-kg weights were combined. The 8-kg measurements were severely limited due to SWE measurement saturation of the tissue samples.

Conclusion: This study suggests that SWE is reliable for measuring capsular tissue stiffness changes in vitro at lower loads (1 and 3 kg) and provides a baseline for the non-invasive evaluation of effects of joint loading and mobilization on capsular tissues in vivo.

Citing Articles

Investigating the Reliability of Shore Hardness in the Design of Procedural Task Trainers.

Kriener K, Sinclair K, Robison G, Lala R, Finley H, Richardson W Bioengineering (Basel). 2025; 12(1.

PMID: 39851315 PMC: 11762807. DOI: 10.3390/bioengineering12010041.


Evaluation of the ulnar nerve with shear-wave elastography: a potential sonographic method for the diagnosis of ulnar neuropathy.

Kim S, Lee G Ultrasonography. 2020; 40(3):349-356.

PMID: 33115185 PMC: 8217804. DOI: 10.14366/usg.20101.

References
1.
Chillemi C, Franceschini V . Shoulder osteoarthritis. Arthritis. 2013; 2013:370231. PMC: 3556427. DOI: 10.1155/2013/370231. View

2.
Mori H, Uemura N, Koga H, Okazaki M . Objective assessment of reconstructed breast hardness using a durometer. Breast Cancer. 2017; 25(1):81-85. DOI: 10.1007/s12282-017-0791-y. View

3.
Muraki T, Yamamoto N, Berglund L, Sperling J, Steinmann S, Cofield R . The effect of cyclic loading simulating oscillatory joint mobilization on the posterior capsule of the glenohumeral joint: a cadaveric study. J Orthop Sports Phys Ther. 2011; 41(5):311-8. DOI: 10.2519/jospt.2011.3448. View

4.
Talbott And N, Witt D . In vivo measurements of humeral movement during posterior glenohumeral mobilizations. J Man Manip Ther. 2016; 24(5):269-276. PMC: 5125433. DOI: 10.1179/2042618615Y.0000000007. View

5.
Johnson A, Godges J, Zimmerman G, Ounanian L . The effect of anterior versus posterior glide joint mobilization on external rotation range of motion in patients with shoulder adhesive capsulitis. J Orthop Sports Phys Ther. 2007; 37(3):88-99. DOI: 10.2519/jospt.2007.2307. View