Computed Optical Coherence Microscopy of Mouse Brain Ex Vivo

Overview
Journal J Biomed Opt
Date 2019 Nov 28
PMID 31773937
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

The compromise between lateral resolution and usable imaging depth range is a bottleneck for optical coherence tomography (OCT). Existing solutions for optical coherence microscopy (OCM) suffer from either large data size and long acquisition time or a nonideal point spread function. We present volumetric OCM of mouse brain with a large depth coverage by leveraging computational adaptive optics (CAO) to significantly reduce the number of OCM volumes that need to be acquired with a Gaussian beam focused at different depths. We demonstrate volumetric reconstruction of mouse brain with lateral resolution of 2.2  μm, axial resolution of 4.7  μm, and depth range of ∼1.2  mm optical path length, using only 11 OCT data volumes acquired on a spectral-domain OCM system. Compared to focus scanning with step size equal to the Rayleigh length of the beam, this is a factor of 4 fewer datasets required for volumetric imaging. Coregistered two-photon microscopy confirmed that CAO-OCM reconstructions can visualize various tissue microstructures in the brain. Our results also highlight the limitations of CAO in highly scattering media, particularly when attempting to reconstruct far from the focal plane or when imaging deep within the sample.

Citing Articles

Optical coherence microscopy with a split-spectrum image reconstruction method for temporal-dynamics contrast-based imaging of intracellular motility.

Kang Y, Canoy R, Jang Y, Santos A, Son I, Kim B Biomed Opt Express. 2023; 14(2):577-592.

PMID: 36874497 PMC: 9979675. DOI: 10.1364/BOE.478264.


Investigation of multiple scattering in space and spatial-frequency domains: with application to the analysis of aberration-diverse optical coherence tomography.

Wu M, Liu S, Leartprapun N, Adie S Biomed Opt Express. 2022; 12(12):7478-7499.

PMID: 35003847 PMC: 8713691. DOI: 10.1364/BOE.439395.


Closed-loop wavefront sensing and correction in the mouse brain with computed optical coherence microscopy.

Liu S, Xia F, Yang X, Wu M, Bizimana L, Xu C Biomed Opt Express. 2021; 12(8):4934-4954.

PMID: 34513234 PMC: 8407825. DOI: 10.1364/BOE.427979.


Capability of physically reasonable OCT-based differentiation between intact brain tissues, human brain gliomas of different WHO grades, and glioma model 101.8 from rats.

Dolganova I, Aleksandrova P, Nikitin P, Alekseeva A, Chernomyrdin N, Musina G Biomed Opt Express. 2020; 11(11):6780-6798.

PMID: 33282523 PMC: 7687948. DOI: 10.1364/BOE.409692.


Bulk-phase-error correction for phase-sensitive signal processing of optical coherence tomography.

Oikawa K, Oida D, Makita S, Yasuno Y Biomed Opt Express. 2020; 11(10):5886-5902.

PMID: 33149994 PMC: 7587287. DOI: 10.1364/BOE.396666.

References
1.
Hillmann D, Franke G, Luhrs C, Koch P, Huttmann G . Efficient holoscopy image reconstruction. Opt Express. 2012; 20(19):21247-63. DOI: 10.1364/OE.20.021247. View

2.
Xu Y, Chng X, Adie S, Boppart S, Carney P . Multifocal interferometric synthetic aperture microscopy. Opt Express. 2014; 22(13):16606-18. PMC: 4162369. DOI: 10.1364/OE.22.016606. View

3.
Lee K, Zhao H, Ibrahim S, Meemon N, Khoudeir L, Rolland J . Three-dimensional imaging of normal skin and nonmelanoma skin cancer with cellular resolution using Gabor domain optical coherence microscopy. J Biomed Opt. 2012; 17(12):126006. PMC: 3512165. DOI: 10.1117/1.JBO.17.12.126006. View

4.
Goergen C, Radhakrishnan H, Sakadzic S, Mandeville E, Lo E, Sosnovik D . Optical coherence tractography using intrinsic contrast. Opt Lett. 2012; 37(18):3882-4. PMC: 3691965. DOI: 10.1364/ol.37.003882. View

5.
Mulligan J, Feng X, Adie S . Quantitative reconstruction of time-varying 3D cell forces with traction force optical coherence microscopy. Sci Rep. 2019; 9(1):4086. PMC: 6411852. DOI: 10.1038/s41598-019-40608-4. View