» Articles » PMID: 3174215

Biomechanics and Gait Analysis in Total Knee Replacement

Overview
Journal Orthop Rev
Specialty Orthopedics
Date 1988 May 1
PMID 3174215
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

A primary goal of total knee replacement has been the relief of pain. As new implant designs evolve and other improvements take place, we must broaden our goals to include increased longevity and an improvement in patient function, especially among younger patients. There is a relationship between the longevity of the implant and patient function, since function determines loads on the joint and the motion of the joint. In addition, ultimate breakdown of the prosthesis depends upon these same loads. This paper will first discuss the relationship between function and some of the intrinsic mechanics of the knee joint, and then the relationship between function and mechanics and the longevity of the implant. It is based on an analysis of patients with a variety of differently designed total knee replacements that replicate, to a greater or lesser degree, the anatomy of the knee joint. Some of the implants sacrifice both anterior and posterior cruciates, and some retain both.

Citing Articles

Elongation Patterns of the Posterior Cruciate Ligament after Total Knee Arthroplasty.

Nasab S, Smith C, Schutz P, Postolka B, Ferguson S, Taylor W J Clin Med. 2020; 9(7).

PMID: 32630654 PMC: 7408829. DOI: 10.3390/jcm9072078.


Gait analysis methodology for the measurement of biomechanical parameters in total knee arthroplasties. A literature review.

Papagiannis G, Triantafyllou A, Roumpelakis I, Papagelopoulos P, Babis G J Orthop. 2018; 15(1):181-185.

PMID: 29657464 PMC: 5895909. DOI: 10.1016/j.jor.2018.01.048.


Are contemporary femoral components sizing and design likely to affect functional results in TKA? A mathematical model of an implanted knee to predict knee forces.

Tecame A, Ferrari M, Violante B, Calafiore G, Papalia R, Adravanti P Musculoskelet Surg. 2018; 102(3):289-297.

PMID: 29404964 DOI: 10.1007/s12306-018-0533-0.


Polyethylene Damage Increases With Varus Implant Alignment in Posterior-stabilized and Constrained Condylar Knee Arthroplasty.

Li Z, Esposito C, Koch C, Lee Y, Padgett D, Wright T Clin Orthop Relat Res. 2017; 475(12):2981-2991.

PMID: 28822068 PMC: 5670063. DOI: 10.1007/s11999-017-5477-4.


The accuracy of the extramedullary and intramedullary femoral alignment system in total knee arthroplasty for varus osteoarthritic knee.

Jung W, Chun C, Lee J, Ha J, Jeong J Knee Surg Sports Traumatol Arthrosc. 2012; 21(3):629-35.

PMID: 22484418 DOI: 10.1007/s00167-012-1994-6.