What is the Safety and Efficacy of the Use of Automated Fastener in Heart Valve Surgery?

Overview
Journal J Card Surg
Date 2019 Nov 15
PMID 31725943
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Introduction: Cor-Knot automated fastener has been used as an adjunct in heart valve surgery to eliminate the need for manual tying during valve implantation. Although reduced operative time and facilitation for minimally invasive surgery are clear benefits, whether their use translates to improved patient outcome remains debatable. This study aims to review the safety and efficacy of automated fasteners in heart valve surgeries.

Method: Specific searches were conducted via online medical databases (Pubmed, Embase, Ovid) between 1950 and June 2019. Longitudinal studies were included that provided operative parameters.

Results: The initial literature search identified 3773 articles, but only eight met the inclusion criteria and were used for analysis: four studies related to aortic valve replacement (AVR), four related to mitral valve (MV) intervention (total n = 810). The meta-analysis revealed the significantly shorter aortic cross-clamp time in the Cor-knot group compared to manual tying, both in AVR and MV surgeries (P < .05). Cardiopulmonary bypass time was significantly shorter in the Cor-knot group when analyzing studies in MV surgery (weighted mean difference [WMD]: 110.0; 95% confidence interval: 12.3-207.7; P = .027) The use of Cor-Knot did not increase the risk of permanent pacemaker implantation, paravalvular leak, and 30-day mortality. The majority of studies reported no change in the length of intensive unit care and total hospital stay.

Conclusion: We confirmed that the majority of existing literatures indicated the safety and intraoperative efficacy with automated fastener application. Nevertheless, there is currently no evidence to support automated fastened sutures can translate its intraoperative advantages to improved patient outcome.

Citing Articles

Efficacy of automated fasteners versus hand-tied knots in cardiac surgery: a systematic review and meta-analysis.

Tharwani Z, Qadeer M, Abdullah A, Ali R, Chaudhary M, Qazi S EXCLI J. 2024; 23:198-211.

PMID: 38487081 PMC: 10938240. DOI: 10.17179/excli2023-6885.


Consensus statement on aortic valve replacement via an anterior right minithoracotomy in the UK healthcare setting.

Vohra H, Salmasi M, Mohamed F, Shehata M, Bahrami B, Caputo M Open Heart. 2023; 10(1).

PMID: 37001910 PMC: 10069572. DOI: 10.1136/openhrt-2022-002194.


A qualitative improvement program for minimally invasive mitral surgery: technical advancements ameliorate outcome and operative times.

Gollmann-Tepekoylu C, Nagele F, Hofer D, Holfeld J, Hirsch J, Oezpeker C Interdiscip Cardiovasc Thorac Surg. 2023; 36(3).

PMID: 36866493 PMC: 9982358. DOI: 10.1093/icvts/ivad030.


Safety and Effectiveness Outcomes of a Novel Automated Titanium Suture Fastener Device Applied for Heart Valve Surgery in an Ovine Model.

Li B, Bai S, Yue G, Zhu J, Zhang M, Yang B Front Cardiovasc Med. 2022; 9:783208.

PMID: 35224036 PMC: 8874148. DOI: 10.3389/fcvm.2022.783208.


Updates on the Latest Surgical Approach of the Aortic Stenosis.

Geicu L, Busuttil O, DOstrevy N, Pernot M, Benali W, Labrousse L J Clin Med. 2021; 10(21).

PMID: 34768660 PMC: 8584939. DOI: 10.3390/jcm10215140.