Bioelectrical Impedance Analysis Is Not Sufficient for Determining Water Deficit in Hypernatremic Patients

Overview
Journal Med Sci Monit
Date 2019 Nov 10
PMID 31705647
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

BACKGROUND Hypernatremia is associated with poor outcomes in critically ill patients, and an accurate assessment of water volume is important to determine appropriate fluid hydration. Bioelectrical impedance analysis (BIA) is a new, noninvasive, and relatively easy method for measuring hydration status. This study aimed to investigate whether bioelectrical impedance measurements of body water could reduce the frequency of blood sampling for fluid replacement in patients with hypernatremia. MATERIAL AND METHODS Fifty-one hospitalized patients were studied with hypernatremia, defined as a serum sodium ≥150 mmol/L determined by laboratory testing. Laboratory and BIA measurements were compared, and water deficiency was calculated with a conventional formula (sodium-corrected Watson formula) and measured by BIA. RESULTS The value of the absolute fluid overload (AFO) equivalent to the overhydration (OH) value, determined using BIA, did not accurately represent water deficit in patients with hypernatremia (r=0.137, P=0.347). Although the total body water (TBW) measured by BIA showed a significant correlation with that determined by the conventional formula (r=0.861, P<0.001), there was a proportional bias (r=0.617, P<0.001). The intracellular water (ICW) measured by BIA underestimated the TBW level calculated by the conventional formula by about 14.06±4.0 L in the Bland-Altman analysis. CONCLUSIONS It is not currently possible to replace blood testing with BIA for assessing volume status in hypernatremic patients. However, ICW value measured by BIA might represent plasma sodium level more accurately than extracellular water (ECW) or TBW value in patients with hypernatremia.

Citing Articles

Acute Water Supplementation Improved the Body Composition of Young Female Adults After Water Restriction of 12 h in Baoding, China: A Randomized Controlled Trial (RCT).

Zhang J, Zhang N, Du S, Liu S, Ma G Front Nutr. 2022; 9:880630.

PMID: 35795583 PMC: 9251362. DOI: 10.3389/fnut.2022.880630.

References
1.
Scheltinga M, Jacobs D, Kimbrough T, Wilmore D . Alterations in body fluid content can be detected by bioelectrical impedance analysis. J Surg Res. 1991; 50(5):461-8. DOI: 10.1016/0022-4804(91)90025-h. View

2.
OBrien C, YOUNG A, Sawka M . Bioimpedance assessment of hypohydration. Med Sci Sports Exerc. 1999; 31(10):1466-71. DOI: 10.1097/00005768-199910000-00017. View

3.
Matthews E, Hosick P . Bioelectrical impedance analysis does not detect an increase in total body water following isotonic fluid consumption. Appl Physiol Nutr Metab. 2019; 44(10):1116-1120. DOI: 10.1139/apnm-2019-0106. View

4.
Gatterer H, Schenk K, Laninschegg L, Schlemmer P, Lukaski H, Burtscher M . Bioimpedance identifies body fluid loss after exercise in the heat: a pilot study with body cooling. PLoS One. 2014; 9(10):e109729. PMC: 4184898. DOI: 10.1371/journal.pone.0109729. View

5.
Malbrain M, Huygh J, Dabrowski W, De Waele J, Staelens A, Wauters J . The use of bio-electrical impedance analysis (BIA) to guide fluid management, resuscitation and deresuscitation in critically ill patients: a bench-to-bedside review. Anaesthesiol Intensive Ther. 2014; 46(5):381-91. DOI: 10.5603/AIT.2014.0061. View