» Articles » PMID: 31688408

Comparison of Locked Plating of Varus Displaced Proximal Humeral Fractures With and Without Fibula Allograft Augmentation

Overview
Journal J Orthop Trauma
Date 2019 Nov 6
PMID 31688408
Citations 9
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: To compare the clinical and radiographic outcomes between patients treated with fibula allograft-augmented locking compression fixation and patients treated with locking compression fixation alone for 2- and 3-part proximal humeral fractures with varus displacement.

Design: Retrospective review.

Setting: Level 1 trauma center.

Patients/participants: One hundred two patients treated with locking plate fixation ± fibular allograft augmentation confirmed intraoperatively by visual inspection to have varus-angulated, 2- and 3-part proximal humerus fractures with at least 45 degrees of varus angulation at the neck/shaft and at least 1 cm of displacement.

Intervention: Proximal humerus locking plate (PHILOS; Synthes, Paoli, PA) with or without fibula allograft augmentation.

Main Outcome Measurements: Statistical analysis to determine the differences between fractures treated with locking compression fixation ± fibula allograft augmentation regarding complications, shoulder reported outcome measures, and patient ROMs (Visual Analog Score (VAS), Disabilities of the Arm, Shoulder and Hand, and Simple Shoulder Test scores). Medical comorbidities as potential risk factors for complication from surgery were also evaluated.

Results: Of 102 surgical cases, 27 were augmented with fibula allograft and 75 were not. Postoperatively, there were 16 noncatastrophic varus collapses of the fracture, 6 catastrophic varus collapses, and 5 deaths. Addition of fibula allograft did not significantly affect postoperative varus collapse, shoulder ROM, pain, or PROMs.

Conclusion: Addition of fibula allograft to patients sustaining varus-angulated, 2- and 3-part proximal humeral fractures conferred no benefit to patient outcomes at our institution.

Level Of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

Citing Articles

Management of extra-articular fracture of the distal humerus with the upside-down use of PHILOS plates in front of the humerus: a retrospective study of 20 patients after 28.3 months.

Li G, Cui Y, Hua X, Liu F, Li D, Lu J BMC Musculoskelet Disord. 2024; 25(1):952.

PMID: 39587632 PMC: 11587592. DOI: 10.1186/s12891-024-08098-2.


Open reduction and internal fixation versus minimally invasive plate osteosynthesis of unstable proximal humerus fractures treated with locking plate and intramedullary allograft: A retrospective study.

Rusimov L, Baltov A, Enchev D, Gueorguiev B, Prodanova K, Hadzhinikolova M Shoulder Elbow. 2024; :17585732241246718.

PMID: 39552652 PMC: 11562148. DOI: 10.1177/17585732241246718.


Novel Use of a Fibular Strut Allograft with Fibular Head in an Elderly Patient with Proximal Humeral Fracture and Severe Metaphyseal Comminution: An Alternative to Shoulder Arthroplasty.

Lim J, Ahn Y, Kim S, Kim M J Clin Med. 2024; 13(8).

PMID: 38673473 PMC: 11050512. DOI: 10.3390/jcm13082200.


Fibula allograft in complex three-part and four-part proximal humeral fractures in active patients, a matched case-control study.

Opperman F, Blaas L, Pape M, Buijs N, Sterkenburg M, Yuan J JSES Int. 2024; 8(1):21-26.

PMID: 38312278 PMC: 10837717. DOI: 10.1016/j.jseint.2023.10.004.


Biomechanical investigation of arm position on deforming muscular forces in proximal humerus fractures.

Chalmers C, Wright D, Patel N, Hitchens H, McGarry M, Lee T Clin Shoulder Elb. 2022; 25(4):282-287.

PMID: 35971598 PMC: 9727481. DOI: 10.5397/cise.2022.00885.