Purpose: High-dose-rate brachytherapy (HDR-BT) is commonly combined with external beam radiation therapy (EBRT) for the treatment of localized prostate cancer. Escalating the HDR-BT dose as far as organ-at-risk (OAR) constraints allow, on a personalized basis, would allow for a reduction in EBRT dose while achieving similar total biologic equivalence. The primary objective of this study was to determine the dosimetric feasibility of escalating the HDR-BT dose from 15 Gy to 16 or 17 Gy while continuing to meet OAR constraints from the original 15 Gy plan on an individualized basis.

Methods And Materials: A total of 53 consecutive HDR-BT plans were retrospectively assessed to determine what percentage of plans could be reoptimized to deliver a dose of 16 Gy or 17 Gy, while meeting defined 15-Gy OAR constraints. Factors independently associated with dose escalation were examined.

Results: Thirty-nine plans (74%) and 2 plans (4%) were successfully escalated to a dose of 16 Gy and 17 Gy, respectively. Rectum V80 and urethra D were independently predictive of the ability to dose escalate to 16 Gy.

Conclusions: Individualized HDR-BT dose escalation beyond 15 Gy without compromising OAR constraints is dosimetrically feasible. This approach could allow for a corresponding reduction of EBRT fractions (ie, from 15 to 12 fractions) and would be beneficial in terms of resource savings for departments, convenience for patients, and potentially better tolerance of treatment with the expected reduction in biologically equivalent doses to OARs. A clinical trial is being developed to investigate the efficacy and tolerance of personalized HDR-BT/EBRT dose fractionation for localized intracapsular prostate cancer.

Citing Articles

Overview of treatment plan quality in a high dose rate prostate brachytherapy workflow.

Panetta J, Veltchev I, Horwitz E, Hallman M, Wong K, Price R Brachytherapy. 2024; 23(6):698-704.

PMID: 39343653 PMC: 11585429. DOI: 10.1016/j.brachy.2024.08.255.

References
1.
Morton G, Chung H, McGuffin M, Helou J, DAlimonte L, Ravi A . Prostate high dose-rate brachytherapy as monotherapy for low and intermediate risk prostate cancer: Early toxicity and quality-of life results from a randomized phase II clinical trial of one fraction of 19Gy or two fractions of 13.5Gy. Radiother Oncol. 2016; 122(1):87-92. DOI: 10.1016/j.radonc.2016.10.019. View

2.
Lauche O, Delouya G, Taussky D, Menard C, Beliveau-Nadeau D, Hervieux Y . Single-fraction high-dose-rate brachytherapy using real-time transrectal ultrasound based planning in combination with external beam radiotherapy for prostate cancer: dosimetrics and early clinical results. J Contemp Brachytherapy. 2016; 8(2):104-9. PMC: 4873550. DOI: 10.5114/jcb.2016.59216. View

3.
Smith G, Pickles T, Crook J, Martin A, Vigneault E, Cury F . Brachytherapy improves biochemical failure-free survival in low- and intermediate-risk prostate cancer compared with conventionally fractionated external beam radiation therapy: a propensity score matched analysis. Int J Radiat Oncol Biol Phys. 2015; 91(3):505-16. DOI: 10.1016/j.ijrobp.2014.11.018. View

4.
Mendez L, Morton G . High dose-rate brachytherapy in the treatment of prostate cancer. Transl Androl Urol. 2018; 7(3):357-370. PMC: 6043748. DOI: 10.21037/tau.2017.12.08. View

5.
Vigneault E, Mbodji K, Magnan S, Despres P, Lavallee M, Aubin S . High-dose-rate brachytherapy boost for prostate cancer treatment: Different combinations of hypofractionated regimens and clinical outcomes. Radiother Oncol. 2017; 124(1):49-55. DOI: 10.1016/j.radonc.2017.06.012. View