» Articles » PMID: 31650272

Analysis of Corneal Stromal Roughness After IFS 150 KHz and LenSx Femtosecond LASIK Flap Creation in Porcine Eyes

Overview
Specialty Ophthalmology
Date 2019 Oct 26
PMID 31650272
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To describe and compare the stromal bed roughness obtained after laser in situ keratomileusis (LASIK) flap creation using a corneal femtosecond laser platform (iFS 150) and a "dual" femtosecond (FS) laser platform (LenSx).

Methods: This ex vivo experimental study was conducted in an animal model using 12 freshly enucleated porcine eyes, six with each femtosecond laser. The standard laser treatment parameters were used for the experiment. After LASIK flap creation, the corneal stromal roughness was assessed using atomic force microscopy (AFM) in contact mode immersed in liquid. In each sample, surface measurements were obtained in 60 regions of six eyes per FS laser in 10 20 × 20-micron areas of the central corneal stroma at 512 × 512-point resolution. The surface roughness was measured and the root-mean-square (RMS) values of the roughness were obtained.

Results: The mean RMS ± standard deviation values were 430 ± 150 nm for the corneal femtosecond laser platform and 370 ± 100 nm for the dual FS laser platform (P < 0.011).

Conclusions: In this experimental study with AFM, we found smoother stromal beds after LASIK flap creation with LenSx compared to iFS 150 kHz. Further studies are needed to understand visual implications of the differences found.

Citing Articles

An optional surgical technique for obtaining lamellar donor grafts: a pilot study.

Liu X, Liu C, Lin H, Shao Y, Zhang L, Bi Y BMC Ophthalmol. 2022; 22(1):137.

PMID: 35337290 PMC: 8957127. DOI: 10.1186/s12886-022-02371-5.


Atomic force microscopy comparative analysis of the surface roughness of two posterior chamber phakic intraocular lens models: ICL versus IPCL.

Gros-Otero J, Ketabi S, Canones-Zafra R, Garcia-Gonzalez M, Villa-Collar C, Casado S BMC Ophthalmol. 2021; 21(1):280.

PMID: 34261440 PMC: 8281652. DOI: 10.1186/s12886-021-02039-6.


Corneal stromal roughness after VisuMax and Intralase femtosecond laser photodisruption: An atomic force microscopy study.

Gros-Otero J, Ketabi S, Canones-Zafra R, Garcia-Gonzalez M, Villa-Collar C, Casado S PLoS One. 2021; 16(5):e0252449.

PMID: 34043738 PMC: 8158881. DOI: 10.1371/journal.pone.0252449.

References
1.
Sarayba M, Ignacio T, Tran D, Binder P . A 60 kHz IntraLase femtosecond laser creates a smoother LASIK stromal bed surface compared to a Zyoptix XP mechanical microkeratome in human donor eyes. J Refract Surg. 2007; 23(4):331-7. DOI: 10.3928/1081-597X-20070401-04. View

2.
Kymionis G, Kontadakis G, Naoumidi I, Kankariya V, Panagopoulou S, Manousaki A . Comparative study of stromal bed of LASIK flaps created with femtosecond lasers (IntraLase FS150, WaveLight FS200) and mechanical microkeratome. Br J Ophthalmol. 2013; 98(1):133-7. DOI: 10.1136/bjophthalmol-2013-304023. View

3.
Moshirfar M, Desautels J, Quist T, Skanchy D, Williams M, Wallace R . Rainbow glare after laser-assisted in situ keratomileusis: a review of literature. Clin Ophthalmol. 2016; 10:2245-2249. PMC: 5108617. DOI: 10.2147/OPTH.S117971. View

4.
Colombo-Barboza M, Colombo-Barboza G, Colombo-Barboza L, Matuoka M, Neto A, de Freitas D . Reproducibility of laser in situ keratomileusis flap thickness using a new multifunctional femtosecond laser platform and correlation with clinical preoperative measurements. J Cataract Refract Surg. 2018; 44(7):811-817. DOI: 10.1016/j.jcrs.2018.05.008. View

5.
Huhtala A, Pietila J, Makinen P, Uusitalo H . Femtosecond lasers for laser in situ keratomileusis: a systematic review and meta-analysis. Clin Ophthalmol. 2016; 10:393-404. PMC: 4788361. DOI: 10.2147/OPTH.S99394. View