Brain-machine interfaces hold promise for the restoration of sensory and motor function and the treatment of neurological disorders, but clinical brain-machine interfaces have not yet been widely adopted, in part, because modest channel counts have limited their potential. In this white paper, we describe Neuralink's first steps toward a scalable high-bandwidth brain-machine interface system. We have built arrays of small and flexible electrode "threads," with as many as 3072 electrodes per array distributed across 96 threads. We have also built a neurosurgical robot capable of inserting six threads (192 electrodes) per minute. Each thread can be individually inserted into the brain with micron precision for avoidance of surface vasculature and targeting specific brain regions. The electrode array is packaged into a small implantable device that contains custom chips for low-power on-board amplification and digitization: The package for 3072 channels occupies less than 23×18.5×2 mm. A single USB-C cable provides full-bandwidth data streaming from the device, recording from all channels simultaneously. This system has achieved a spiking yield of up to 70% in chronically implanted electrodes. Neuralink's approach to brain-machine interface has unprecedented packaging density and scalability in a clinically relevant package.

Citing Articles

Recent Progress in Flexible Microelectrode Arrays for Combined Electrophysiological and Electrochemical Sensing.

Siwakoti U, Jones S, Kumbhare D, Cui X, Castagnola E Biosensors (Basel). 2025; 15(2).

PMID: 39997002 PMC: 11853293. DOI: 10.3390/bios15020100.


Efficient Spatial Estimation of Perceptual Thresholds for Retinal Implants via Gaussian Process Regression.

Sadeghi R, Beyeler M ArXiv. 2025; .

PMID: 39990794 PMC: 11844632.


Bio-inspired electronics: Soft, biohybrid, and "living" neural interfaces.

Boufidis D, Garg R, Angelopoulos E, Cullen D, Vitale F Nat Commun. 2025; 16(1):1861.

PMID: 39984447 PMC: 11845577. DOI: 10.1038/s41467-025-57016-0.


Community perspectives regarding brain-computer interfaces: A cross-sectional study of community-dwelling adults in the UK.

El-Osta A, Al Ammouri M, Khan S, Altalib S, Karki M, Riboli-Sasco E PLOS Digit Health. 2025; 4(2):e0000524.

PMID: 39908280 PMC: 11798465. DOI: 10.1371/journal.pdig.0000524.


Bioaugmented design and functional evaluation of low damage implantable array electrodes.

Wang L, Zhang C, Hao Z, Yao S, Bai L, Oliveira J Bioact Mater. 2025; 47:18-31.

PMID: 39872211 PMC: 11762938. DOI: 10.1016/j.bioactmat.2024.12.033.


References
1.
Chorover S, DeLuca A . A sweet new multiple electrode for chronic single unit recording in moving animals. Physiol Behav. 1972; 9(4):671-4. DOI: 10.1016/0031-9384(72)90030-3. View

2.
Collinger J, Wodlinger B, Downey J, Wang W, Tyler-Kabara E, Weber D . High-performance neuroprosthetic control by an individual with tetraplegia. Lancet. 2012; 381(9866):557-64. PMC: 3641862. DOI: 10.1016/S0140-6736(12)61816-9. View

3.
Saxena T, Karumbaiah L, Gaupp E, Patkar R, Patil K, Betancur M . The impact of chronic blood-brain barrier breach on intracortical electrode function. Biomaterials. 2013; 34(20):4703-13. DOI: 10.1016/j.biomaterials.2013.03.007. View

4.
Zhou A, Santacruz S, Johnson B, Alexandrov G, Moin A, Burghardt F . A wireless and artefact-free 128-channel neuromodulation device for closed-loop stimulation and recording in non-human primates. Nat Biomed Eng. 2019; 3(1):15-26. DOI: 10.1038/s41551-018-0323-x. View

5.
Siegle J, Lopez A, Patel Y, Abramov K, Ohayon S, Voigts J . Open Ephys: an open-source, plugin-based platform for multichannel electrophysiology. J Neural Eng. 2017; 14(4):045003. DOI: 10.1088/1741-2552/aa5eea. View