Background: A Danish study showed that 90% of the pediatric patients who participated had some time experienced dermatological complications due to treatment with continuous subcutaneous insulin infusion (CSII). This follow-up study describes dermatological complications due to CSII and/or continuous glucose monitoring (CGM) between the two study periods and includes health-related quality of life (HrQoL) measurements.

Methods: A total of 138 patients (95%) out of 145 patients from the initial study answered an online questionnaire regarding dermatological complications related to CSII and/or CGM, five months later. A second questionnaire (DISABKIDS) regarding HrQoL was sent out to those 138 of which 111 patients completed it. The patients were aged from 2 to 20 years. Descriptive statistics, χ tests, and univariate and multivariate analyses were used to analyze the data.

Results: In total, 81% of the 138 patients continued to have dermatological complications at follow-up. Itching was the most frequently reported complication. Patients using Enlite reported more dermatological complications than those using Libre. In total, 79% of the patients who used barrier cream in the initial study still had dermatological complications five months later. Age, gender, Body Mass Index (BMI), or HbA1c levels showed no significant association with dermatological complications. Patients who perceived dermatological complications as a greater problem had lower HrQoL scores.

Conclusion: Once dermatological complications start to appear, they become chronic, indicating that the treatments currently available are inadequate. Patients perceiving dermatological complications as a greater problem were associated with lower HrQoL. These findings highlight the need for additional preventive studies.

Citing Articles

Allergic contact dermatitis caused by glucose sensors and insulin pumps: A full review: Part 1: Sensors and pumps, adverse cutaneous reactions, allergens, and diabetes devices causing allergic contact dermatitis.

de Groot A, van Oers E, Ipenburg N, Rustemeyer T Contact Dermatitis. 2024; 92(2):87-112.

PMID: 39600106 PMC: 11710928. DOI: 10.1111/cod.14698.


Barriers to Type 1 Diabetes Adherence in Adolescents.

Azar S, Maroun Abou Jaoude N, Kedzia A, Niechcial E J Clin Med. 2024; 13(19).

PMID: 39407728 PMC: 11477045. DOI: 10.3390/jcm13195669.


Insulin Pump Therapy and Adverse Skin Reactions With Focus on Allergic Contact Dermatitis in Individuals Living With Diabetes Mellitus: A Systematic Review and Clinical-Based Update.

von Kobyletzki L, Ulriksdotter J, von Kobyletzki E, Mowitz M, Jendle J, Svedman C J Diabetes Sci Technol. 2024; 18(6):1300-1312.

PMID: 38853748 PMC: 11535278. DOI: 10.1177/19322968241252613.


Diabetes Technology Meeting 2021.

Xu N, Nguyen K, DuBord A, Pickup J, Sherr J, Teymourian H J Diabetes Sci Technol. 2022; 16(4):1016-1056.

PMID: 35499170 PMC: 9264449. DOI: 10.1177/19322968221090279.


Technologies for Type 1 Diabetes and Contact Dermatitis: Therapeutic Tools and Clinical Outcomes in a Cohort of Pediatric Patients.

Passanisi S, Salzano G, Galletta F, Aramnejad S, Caminiti L, Pajno G Front Endocrinol (Lausanne). 2022; 13:846137.

PMID: 35370980 PMC: 8965381. DOI: 10.3389/fendo.2022.846137.


References
1.
Kamann S, Oppel E . Hydrocolloid blister plaster decreases allergic contact dermatitis caused by Freestyle Libre and isobornyl acrylate. Contact Dermatitis. 2019; 81(5):380-381. DOI: 10.1111/cod.13329. View

2.
Lustman P, Clouse R . Depression in diabetic patients: the relationship between mood and glycemic control. J Diabetes Complications. 2005; 19(2):113-22. DOI: 10.1016/j.jdiacomp.2004.01.002. View

3.
Simeoni M, Schmidt S, Muehlan H, Debensason D, Bullinger M . Field testing of a European quality of life instrument for children and adolescents with chronic conditions: the 37-item DISABKIDS Chronic Generic Module. Qual Life Res. 2007; 16(5):881-93. DOI: 10.1007/s11136-007-9188-2. View

4.
Schober E, Rami B . Dermatological side effects and complications of continuous subcutaneous insulin infusion in preschool-age and school-age children. Pediatr Diabetes. 2009; 10(3):198-201. DOI: 10.1111/j.1399-5448.2008.00477.x. View

5.
Berg A, Norgaard K, Thyssen J, Zachariae C, Hommel E, Rytter K . Skin Problems Associated with Insulin Pumps and Sensors in Adults with Type 1 Diabetes: A Cross-Sectional Study. Diabetes Technol Ther. 2018; 20(7):475-482. DOI: 10.1089/dia.2018.0088. View