» Articles » PMID: 31581095

A 3 Mm × 3 Mm Fully Integrated Wireless Power Receiver and Neural Interface System-on-Chip

Overview
Publisher IEEE
Date 2019 Oct 4
PMID 31581095
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

A miniaturized, fully integrated wireless power receiver system-on-chip with embedded 16-channel electrode array and data transceiver for electrocortical neural recording and stimulation is presented. An H-tree power and signal distribution network throughout the SoC maintains high quality factor up to 11 in the on-chip receiver coil at 144 MHz resonant frequency while rejecting RF interference in sensitive neural interface circuits owing to its perpendicular and equidistant geometry. A multi-mode buck-boost resonant regulating rectifier (B R ) offers greater than 11-dB input dynamic range in RF reception and less than 1 mV overshoot in transient load regulation. At 10 mm link distance, the 9 mm neural interface SoC fabricated in a 180 nm silicon-on-insulator (SOI) process attains an overall wireless power transmission system efficiency (WSE) of 3.4% in driving a 160  μW load yielding a WSE figure-of-merit of 131, while maintaining signal integrity in analog recording and wireless data transmission that comprise the on-chip load.

Citing Articles

Passive Impedance-Matched Neural Recording Systems for Improved Signal Sensitivity.

Sayeed S, Al Duhni G, Navaz H, Volakis J, Pulugurtha M Sensors (Basel). 2023; 23(14).

PMID: 37514733 PMC: 10385688. DOI: 10.3390/s23146441.


Magnetoelectric Bio-Implants Powered and Programmed by a Single Transmitter for Coordinated Multisite Stimulation.

Yu Z, Chen J, He Y, Alrashdan F, Avants B, Singer A IEEE J Solid-State Circuits. 2022; 57(3):818-830.

PMID: 36275505 PMC: 9581110. DOI: 10.1109/jssc.2021.3129993.


High-density neural recording system design.

Lee H, Eom K, Park M, Ku S, Lee K, Lee H Biomed Eng Lett. 2022; 12(3):251-261.

PMID: 35892035 PMC: 9308855. DOI: 10.1007/s13534-022-00233-z.


Full-duplex enabled wireless power transfer system via textile for miniaturized IMD.

Lee J, Bae B, Kim B, Lee B Biomed Eng Lett. 2022; 12(3):295-302.

PMID: 35875693 PMC: 9288664. DOI: 10.1007/s13534-022-00237-9.


A 13.56-MHz -25-dBm-Sensitivity Inductive Power Receiver System-on-a-Chip With a Self-Adaptive Successive Approximation Resonance Compensation Front-End for Ultra-Low-Power Medical Implants.

Lyu H, Babakhani A IEEE Trans Biomed Circuits Syst. 2020; 15(1):80-90.

PMID: 33373302 PMC: 9215201. DOI: 10.1109/TBCAS.2020.3047827.