» Articles » PMID: 31544055

Gas Sensor Array System Properties for Detecting Bacterial Biofilms

Overview
Date 2019 Sep 24
PMID 31544055
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Gas sensor array system is a device that mimics the work of how the nose smells using the gas sensors that could give response toward specific odors. It is used for characterizing the different blended gas that is suited with the biological working nose principle. Thus, it could be used to detect the dental and oral diseases. Periodontitis is one of the diseases caused by the damage on the teeth due to the chronic infection on the gingival structure marked with bacterial plaque and calculus. This study aims to develop an electric nose for odor detection application on the periodontal bacterial biofilm as early detection device for dental and oral disease.

Methods: This device is designed as a portable device to ease the data acquisition. The measured data were stored at a database system connected to a real-time computer. A gas array sensor system with six gas sensors (TGS 826, TGS 2602, TGS 2600, TGS 2611, TGS 2612, and TGS 2620) has been assembled for the early detection application for dental and oral disease excreted by the bacterial biofilm that caused dental and oral disease, including , and .

Results: TGS 826 and TGS 2602 sensor had the best response showed by the high ADC delta value.

Conclusion: GS 826 and TGS 2602 sensor could be used as a candidate for early detection device for dental and oral disease.

Citing Articles

Nanotechnology improves the detection of bacteria: Recent advances and future perspectives.

Takallu S, Aiyelabegan H, Zomorodi A, Alexandrovna K, Aflakian F, Asvar Z Heliyon. 2024; 10(11):e32020.

PMID: 38868076 PMC: 11167352. DOI: 10.1016/j.heliyon.2024.e32020.


A dedicated electronic nose combined with chemometric methods for detection of adulteration in sesame oil.

Hosseini H, Minaei S, Beheshti B J Food Sci Technol. 2023; 60(10):2681-2694.

PMID: 37599854 PMC: 10439068. DOI: 10.1007/s13197-023-05792-2.


Gas Array Sensors based on Electronic Nose for Detection of Tuna () Contaminated by .

Astuti S, Isyrofie A, Nashichah R, Kashif M, Mujiwati T, Susilo Y J Med Signals Sens. 2023; 12(4):306-316.

PMID: 36726418 PMC: 9885512. DOI: 10.4103/jmss.jmss_139_21.


Recording the Presence of Colonies on MYPGP Substrates Using a Multi-Sensor Array Based on Solid-State Gas Sensors.

Bak B, Wilk J, Artiemjew P, Wilde J Sensors (Basel). 2021; 21(14).

PMID: 34300655 PMC: 8309915. DOI: 10.3390/s21144917.

References
1.
Persson S . Hydrogen sulfide and methyl mercaptan in periodontal pockets. Oral Microbiol Immunol. 1992; 7(6):378-9. DOI: 10.1111/j.1399-302x.1992.tb00641.x. View

2.
Almas K, Al-Hawish A, Al-Khamis W . Oral hygiene practices, smoking habit, and self-perceived oral malodor among dental students. J Contemp Dent Pract. 2003; 4(4):77-90. View

3.
Paulino T, Ribeiro K, Thedei Jr G, Tedesco A, Ciancaglini P . Use of hand held photopolymerizer to photoinactivate Streptococcus mutans. Arch Oral Biol. 2005; 50(3):353-9. DOI: 10.1016/j.archoralbio.2004.09.002. View

4.
Schulz S, Dickschat J . Bacterial volatiles: the smell of small organisms. Nat Prod Rep. 2007; 24(4):814-42. DOI: 10.1039/b507392h. View

5.
Imbronito A, Okuda O, Maria de Freitas N, Lotufo R, Nunes F . Detection of herpesviruses and periodontal pathogens in subgingival plaque of patients with chronic periodontitis, generalized aggressive periodontitis, or gingivitis. J Periodontol. 2008; 79(12):2313-21. DOI: 10.1902/jop.2008.070388. View