» Articles » PMID: 31531552

Clinical Time and Postoperative Sensitivity After Use of Bulk-fill (syringe and Capsule) Vs. Incremental Filling Composites: a Randomized Clinical Trial

Overview
Journal Braz Oral Res
Specialty Dentistry
Date 2019 Sep 19
PMID 31531552
Citations 11
Authors
Affiliations
Soon will be listed here.
Abstract

The objectives of this double-blind randomized clinical trial were to compare (a) the clinical times and (b) the occurrence and severity of postoperative sensitivity, of posterior restoration that used a universal adhesive, in a self-etch or selective enamel-etching technique, along with incremental or bulk-fill composites (presented in syringes or capsules). A total of 295 posterior restorations were placed according to the following groups: SETB - self-etch/bulk-fill in syringe; SETC - self-etch/bulk-fill in capsules; SETI - self-etch/incremental; SEEB - selective enamel-etching/bulk-fill in syringe; SEEC - selective enamel-etching/bulk-fill in capsules; and SEEI - selective enamel-etching/incremental. Clinical time was assessed by a reason (s/mm3) between the total volume of resin inserted and the total time required to perform the restorations. Postoperative sensitivity was evaluated using two scales (Numeric Rating Scale and Visual Analogue Scale). Mean clinical time results, analyzed by Wald's Chi-square, showed significant statistical differences among all groups (p<0.001), indicating that the restorative strategy affected the time required for the restoration. A generalized estimating equation model statistical analysis, performed to compare postoperative sensitivity, showed that neither the restorative technique, the adhesive strategy nor the presentation mode of the bulk-fill composite affected the overall risk of postoperative sensitivity (4.06 [2.22-6.81]). The use of bulk-fill composite, presented in capsules or syringes, is less time consuming and does not increase the risk or intensity of postoperative sensitivity relative to the traditional incremental technique.

Citing Articles

Clinical evaluation of SonicFill bulk resin technique in the restoration of proximal deep caries of primary molars: a two-year randomized controlled trial.

Yang Y, Lei H, Liu Y, Xia B BMC Oral Health. 2024; 24(1):1461.

PMID: 39627729 PMC: 11613801. DOI: 10.1186/s12903-024-05242-1.


Postoperative sensitivity of composites using novel Bacillus subtilis nanofortified adhesives: a triple-blind study.

Amir N, Mansoor A, Eeman N, Ahmed M, Mansoor E, Hussain K BMC Oral Health. 2024; 24(1):1077.

PMID: 39267015 PMC: 11396156. DOI: 10.1186/s12903-024-04825-2.


Clinical Efficacy of a Novel Titania Nanoparticle-Reinforced Bonding Agent in Reducing Post-Restorative Sensitivity: A randomized clinical trial.

Amir N, Mansoor A, Noor N, Hussain K Pak J Med Sci. 2024; 40(7):1332-1337.

PMID: 39092050 PMC: 11255811. DOI: 10.12669/pjms.40.7.8779.


Impact of repeated preheating of bulk-fill resin composite on postoperative hypersensitivity; a randomized controlled clinical trial.

Elkady M, Abdelhakim S, Riad M BMC Oral Health. 2024; 24(1):453.

PMID: 38622629 PMC: 11017642. DOI: 10.1186/s12903-024-04170-4.


The clinical performance of bulk-fill versus the incremental layered application of direct resin composite restorations: a systematic review.

Sengupta A, Naka O, Mehta S, Banerji S Evid Based Dent. 2023; 24(3):143.

PMID: 37402908 PMC: 10516750. DOI: 10.1038/s41432-023-00905-4.