Purpose: Stiffness is a common problem following total knee arthroplasty (TKA). Mal-rotated components have been claimed to be the major cause of pain and limited motion after TKA. The present study investigates whether intra-operative intentional malrotation of the tibial component would change in vivo kinematics. The hypothesis is excessive internal rotation of the tibial component would result in postoperative extension deficit.

Methods: Thirty-one patients were enrolled in this study. After completing bony cuts and proper soft tissue balancing, the femoral and tibial trials were impacted and fixed using small pins. Lateral radiographs were used to measure and compare intraoperative full knee extension during normal and after intentional internal rotation of the tibial component. The extension deficit angles were also compared between the posterior stabilised (PS) and cruciate retaining (CR) implants.

Results: For normal tibial component rotation, the median (interquartile range) extension deficit was 0° (4). The mean tibial trial intentional internal rotation was 21.2° (± 4.5). The median (interquartile range) extension deficit significantly increased to 6° (4) after tibial component internal rotation (p = 0.001). The use of PS spacers resulted in a significantly greater extension deficit after intentional internal rotation 9° (5) compared to that of the CR implant 1° (4) (p = 0.001).

Conclusion: Internal rotation of the tibial component in total knee arthroplasty can lead to postoperative extension deficit. This could be attributed to interference with "screw home" mechanism that requires full external rotation of the tibia on the femur. Consequently, this deficit may cause pain and knee stiffness following TKA.

Level Of Evidence: III.

Citing Articles

Curve-on-curve technique is more reliable than free-floating technique for tibial components positioning in posterior stabilized total knee arthroplasty using symmetrical tibial components in varus osteoarthritis.

Elkabbani M, Saied A, Abouelnas B, Dragos A, Osman A, Tarabichi S BMC Musculoskelet Disord. 2024; 25(1):1009.

PMID: 39668343 PMC: 11636221. DOI: 10.1186/s12891-024-07975-0.


Anteroposterior axis of the tibia for kinematic aligned total knee arthroplasty.

Toyooka S, Arai N, Masuda H, Kawano H, Nakagawa T J Exp Orthop. 2024; 11(4):e70087.

PMID: 39582765 PMC: 11582684. DOI: 10.1002/jeo2.70087.


Comparison of the coverage and rotation of asymmetrical and symmetrical tibial components: a systematic review and meta-analysis.

Zhang Z, Zhang T, Zhang L, Chen Z, Zhao H, Kuang J BMC Musculoskelet Disord. 2024; 25(1):336.

PMID: 38671454 PMC: 11046884. DOI: 10.1186/s12891-024-07466-2.


Coronal Knee Alignment and Tibial Rotation in Total Knee Arthroplasty: A Prospective Cohort Study of Patients with End-Stage Osteoarthritis.

Strahovnik A, Strahovnik I, Fokter S Bioengineering (Basel). 2024; 11(3).

PMID: 38534570 PMC: 10968541. DOI: 10.3390/bioengineering11030296.


Prediction of knee biomechanics with different tibial component malrotations after total knee arthroplasty: conventional machine learning vs. deep learning.

Zhang Q, Li Z, Chen Z, Peng Y, Jin Z, Qin L Front Bioeng Biotechnol. 2024; 11:1255625.

PMID: 38260731 PMC: 10800660. DOI: 10.3389/fbioe.2023.1255625.