Overview
Journal Biomed Res Int
Publisher Wiley
Date 2019 Aug 31
PMID 31467901
Citations 17
Authors
Affiliations
Soon will be listed here.
Abstract

Recent data indicates limited awareness and compliance on infection prevention procedures by dental offices and by dental laboratories. Guidelines for infection prevention in dentistry have been published by Centres for Disease Control and Prevention since 2003; the section "IX-Special consideration" includes a subsection concerning the prevention in dental laboratories, but it has not been modernised in later versions to fit the needs of traditional and computer-aided technology. Traditional techniques required disinfecting items (impression, chewing waxes, and appliances) with well-suited products, which are also chosen for limiting impression changes or appliance deterioration. Effective procedures are available with difficulties. Some of these contain irritant or non-eco-friendly disinfectants. The transport of impression, to dental laboratories, is often delayed with limited precautions for limiting cross-infection. Gypsum casts are frequently contaminated mainly by bacteria and their antibiotic-resistant strains and even stored for long periods during dental implant supported restoration and orthodontic therapy, becoming a hidden source of infection. Nowadays, computer-aided design/computer-aided manufacturing technology seems to be an interesting way to promote both business and safety, being more comfortable for patients and more accurate than traditional technology. A further advantage is easier infection prevention since, for the most part, mainly digital impression and casts are not a source of cross-infection and the transport of contaminated items is reduced and limited to try-in stages. Nevertheless, a peculiar feature is that a digital electronic file is of course unalterable, but may be ruined by a computer virus. Additionally, the reconditioning of scanner tips is determinant for the optical characteristics and long term use of the scanner, but information for its reconditioning from producers is often limited. This study focuses on some critical points including (a) insufficient guidelines, (b) choice of proper procedure for scanner reconditioning, and (c) data protection in relation to patient privacy.

Citing Articles

Knowledge, Attitude, and Practices toward the Novel Coronavirus Infection in Dental Laboratories in the Kingdom of Saudi Arabia: Cross-Sectional Study.

Alsadon O, Alayadi H, Alageel O, Vellappally S, Almansour H, Alsarani M J Pharm Bioallied Sci. 2024; 16(Suppl 2):S1505-S1509.

PMID: 38882746 PMC: 11174290. DOI: 10.4103/jpbs.jpbs_1144_23.


Comparative analysis of dimensional changes in autoclavable polyvinyl siloxane (PVS) impressions under various Sterilization/Disinfection Protocols: A randomized controlled trial.

Taymour N, Hussein Abdel Kader S, Aboushelib M, Gad M Saudi Dent J. 2024; 36(4):603-609.

PMID: 38690388 PMC: 11056420. DOI: 10.1016/j.sdentj.2024.01.016.


Mechanical shock test simulation analysis of butterfly valves developed for the naval defense industry and evaluation of real test and production data.

Ozkan E Sci Rep. 2024; 14(1):9692.

PMID: 38678038 PMC: 11055919. DOI: 10.1038/s41598-024-60302-4.


Mechanical Properties of 3D Printed Orthodontic Retainers.

Firlej M, Zaborowicz K, Zaborowicz M, Firlej E, Domagala I, Pieniak D Int J Environ Res Public Health. 2022; 19(9).

PMID: 35565167 PMC: 9100403. DOI: 10.3390/ijerph19095775.


Pros and Cons of CAD/CAM Technology for Infection Prevention in Dental Settings during COVID-19 Outbreak.

Barenghi L, Barenghi A, Garagiola U, Di Blasio A, Gianni A, Spadari F Sensors (Basel). 2022; 22(1).

PMID: 35009586 PMC: 8747329. DOI: 10.3390/s22010049.


References
1.
Sofou A, Larsen T, Fiehn N, Owall B . Contamination level of alginate impressions arriving at a dental laboratory. Clin Oral Investig. 2002; 6(3):161-5. DOI: 10.1007/s00784-002-0173-4. View

2.
Kakaboura A, Tzoutzas J, Pitsinigos D, Vougiouklakis G . The effect of sterilization methods on the light transmission characteristics and structure of light-curing tips. J Oral Rehabil. 2004; 31(9):918-23. DOI: 10.1111/j.1365-2842.2004.01314.x. View

3.
Egusa H, Watamoto T, Abe K, Kobayashi M, Kaneda Y, Ashida S . An analysis of the persistent presence of opportunistic pathogens on patient-derived dental impressions and gypsum casts. Int J Prosthodont. 2008; 21(1):62-8. View

4.
Egusa H, Watamoto T, Matsumoto T, Abe K, Kobayashi M, Akashi Y . Clinical evaluation of the efficacy of removing microorganisms to disinfect patient-derived dental impressions. Int J Prosthodont. 2009; 21(6):531-8. View

5.
Miyazaki T, Hotta Y, Kunii J, Kuriyama S, Tamaki Y . A review of dental CAD/CAM: current status and future perspectives from 20 years of experience. Dent Mater J. 2009; 28(1):44-56. DOI: 10.4012/dmj.28.44. View