» Articles » PMID: 31450469

Electrochemical Aptasensor Based on Conductive Supramolecular Polymer Hydrogels for Thrombin Detection with High Selectivity

Overview
Journal Talanta
Publisher Elsevier
Specialty Chemistry
Date 2019 Aug 28
PMID 31450469
Citations 13
Authors
Affiliations
Soon will be listed here.
Abstract

Herein, we synthesized a kind of conductive supramolecular polymer hydrogel (CSPH) based on polyaniline (PANI) which can not only improve the conductivity but also promote antifouling performance of the aptasensor for the specific recruitment of thrombin (TB) from complex samples. With the electrochemical copolymerization of aniline (AN) and 3-aminophenylboronic acid (ABA) on glassy carbon electrode (GCE), the electrode was then inserted into the polyvinyl alcohol (PVA) solution to obtain robust CSPH through boric acid groups incorporated onto PANI to cause gelation of PVA solution, owing to the hydrophilicity of CSPH and nearly electrical neutrality, the modified electrode is antifouling without integration of other antifouling materials. A sandwich-type electrochemical aptasensor was constructed on the CSPH based electrode interfaces. Thrombin aptamer 1 (TBA1) were modified on the CSPH through amide bond, and thrombin aptamer 2 modified magnetic nanoparticles (MNP-TBA2) are used as signal amplification probes, the aptasensor has good sensitivity with a linear range from 1 pmol/L to 10 nmol/L and has a detection limit down to 0.64 pmol/L. The strategy of utilizing eletropolymerization of CSPH films to undergo highly selective thrombin recognition is, of course, readily extended to a broad range of targets in the real samples, and the recovery was ranging from 95.2% to 106.3% and RSDs varying from 2.3% to 4.5%.

Citing Articles

Truncated Electrochemical Aptasensor with Enhanced Antifouling Capability for Highly Sensitive Serotonin Detection.

Hu Z, Zhu R, Figueroa-Miranda G, Zhou L, Feng L, Offenhausser A Biosensors (Basel). 2023; 13(9).

PMID: 37754115 PMC: 10527390. DOI: 10.3390/bios13090881.


An off-on fluorescence aptasensor for trace thrombin detection based on FRET between CdS QDs and AuNPs.

Li P, Luo C, Chen X, Huang C RSC Adv. 2022; 12(55):35763-35769.

PMID: 36545096 PMC: 9749934. DOI: 10.1039/d2ra06891e.


Thrombin Determination Using Graphene Oxide Sensors with Co-Assisted Amplification.

Liu L, Li Q, Shi H, Gao L Micromachines (Basel). 2022; 13(9).

PMID: 36144058 PMC: 9502102. DOI: 10.3390/mi13091435.


Recent Progresses in Development of Biosensors for Thrombin Detection.

Eivazzadeh-Keihan R, Saadatidizaji Z, Maleki A, de la Guardia M, Mahdavi M, Barzegar S Biosensors (Basel). 2022; 12(9).

PMID: 36140153 PMC: 9496736. DOI: 10.3390/bios12090767.


A short review on the synthesis and advance applications of polyaniline hydrogels.

Mir A, Kumar A, Riaz U RSC Adv. 2022; 12(30):19122-19132.

PMID: 35865573 PMC: 9244896. DOI: 10.1039/d2ra02674k.