» Articles » PMID: 31416119

Gold Plate Electrodes Functionalized by Multiwall Carbon Nanotube Film for Potentiometric Thallium(I) Detection

Overview
Date 2019 Aug 17
PMID 31416119
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

Solid-contact potentiometric ion-selective electrodes (SC-ISEs) for thallium determination have been designed using multiwall carbon nanotubes (MWCNTs) as the ion-to-electron transducer. Dispersed MWCNTs were drop-casted over a gold plate electrode. Two different crown ethers were used in the sensing membrane for the recognition of thallium (I). Sensorsbased on dibenzo-18-crown-6 (DB18C6) as a neutral carrier and NaTPB as an anionic additive exhibited a near Nernstian response of 57.3 mV/decade towards Tl ions over the activity range 4.5 × 10-7.0 × 10 M, with a limit of detection of 3.2 × 10 M. The time required to achieve 95% of the steadyequilibrium potential was <10 s. The complex formation constant (log ) between dibenzo-18-crown-6 and thallium (I) (i.e., 5.99) was measured using the sandwich membrane technique. The potential response was pH independent over the range 3.0-9.5. The introduction of MWCNTs as an electron-ion-transducer layer between gold plate and the sensing membrane lead to a smaller membrane resistance and a large double layer capacitance, which was proven using impedance spectra and chronopotentiometry (i.e., 114.9 ± 12 kΩ, 52.1 ± 3.3 pF, 200 ± 13.2 kΩ, and 50 ± 4.2 µF). Additionally, reduction ofthe water layer between the sensing membrane and the underlying conductor wastested. Thus, it is clear that MWCNTs can be used as a transducing layer in SC-ISEs. The proposed sensor was introduced as an indicator electrode for potentiometric titration of single and ternary mixtures of I, Br, and S anions.

References
1.
Duzgun A, Zelada-Guillen G, Crespo G, Macho S, Riu J, Rius F . Nanostructured materials in potentiometry. Anal Bioanal Chem. 2010; 399(1):171-81. DOI: 10.1007/s00216-010-3974-3. View

2.
Fouskaki M, Chaniotakis N . Fullerene-based electrochemical buffer layer for ion-selective electrodes. Analyst. 2008; 133(8):1072-5. DOI: 10.1039/b719759d. View

3.
Amr A, Al-Omar M, Kamel A, A Elsayed E . Single-Piece Solid Contact Cu-Selective Electrodes Based on a Synthesized Macrocyclic Calix[4]arene Derivative as a Neutral Carrier Ionophore. Molecules. 2019; 24(5). PMC: 6429070. DOI: 10.3390/molecules24050920. View

4.
Marczenko Z, Kalowska H, Mojski M . Extraction-spectrophotometric determination of thallium in high-purity indium. Talanta. 1974; 21(1):93-7. DOI: 10.1016/0039-9140(74)80067-6. View

5.
Lu T, Yang H, Sun I . Square-wave anodic stripping voltammetric determination of thallium(I) at a Nafion/mercury film modified electrode. Talanta. 2008; 49(1):59-68. DOI: 10.1016/s0039-9140(98)00360-9. View