» Articles » PMID: 31365582

Reliability of a Portable Device for Quantifying Tone and Stiffness of Quadriceps Femoris and Patellar Tendon at Different Knee Flexion Angles

Overview
Journal PLoS One
Date 2019 Aug 1
PMID 31365582
Citations 40
Authors
Affiliations
Soon will be listed here.
Abstract

The reliability of MyotonPRO that can monitor the mechanical properties of tissues is still unclear. This study aimed to analyze the within-day inter-operator and between-day intra-operator reliability of MyotonPRO for assessing tone and stiffness of quadriceps femoris and patellar tendon at different knee angles. The tone and stiffness of healthy participants (15 males and 15 females, aged 24.7±1.6 years) in the supine and resting position were measured using the MyotonPRO device. The measurements were quantified at 0°, 30°, 60°, and 90° of knee flexion. The intraclass correlation coefficient (ICC), standard error of measurement (SEM), and minimal detectable change (MDC) were calculated and a Bland-Altman analysis was conducted to estimate reliability. The results indicated excellent inter-operator reliability (ICC > 0.78) and good to excellent intra-operator reliability (ICC > 0.41). The inter-operator SEM measurements ranged between 0.1-0.9 Hz and 3.8-37.9 N/m, and intra-operator SEM ranged between 0.5-1.3 Hz and 7.9-52.0 N/m. The inter-operator MDC ranged between 0.3-2.5 Hz and 10.5-105.1 N/m, and intra-operator SEM ranged between 1.1-3.3 Hz and 21.9-144.1 N/m. The agreement of inter-operator was better than that of intra-operator. The study concluded that MyotonPRO is a reliable device to detect the tone and stiffness of quadriceps femoris and patellar tendon.

Citing Articles

Immediate Effect of Compression Contrast Therapy on Quadriceps Femoris Muscles' Regeneration in MMA Fighters.

Trybulski R, Roczniok R, Galeziok K, Matuszczyk F, Bichowska-Paweska M, Wilk M J Clin Med. 2024; 13(23).

PMID: 39685751 PMC: 11642141. DOI: 10.3390/jcm13237292.


Intra-rater and inter-rater reliability of a handheld myotonometer measuring myofascial stiffness of lower lumbar myofascial tissue in healthy adults.

Valenti F, Meden S, Frangez M, Vauhnik R PeerJ. 2024; 12:e18524.

PMID: 39575173 PMC: 11580663. DOI: 10.7717/peerj.18524.


The Effects of Combined Contrast Heat Cold Pressure Therapy on Post-Exercise Muscle Recovery in MMA Fighters: A Randomized Controlled Trial.

Trybulski R, Zebrowska A, Bichowska-Paweska M, Kuzdzal A, Ryszkiel I, Silva R J Hum Kinet. 2024; 94:127-146.

PMID: 39563772 PMC: 11571465. DOI: 10.5114/jhk/190220.


Influence of Training Load on Muscle Contractile Properties in Semi-Professional Female Soccer Players Across a Competitive Microcycle: A Pilot Study.

Rey E, Lois-Abal M, Padron-Cabo A, Lorenzo-Martinez M, Costa P Sensors (Basel). 2024; 24(21).

PMID: 39517893 PMC: 11548700. DOI: 10.3390/s24216996.


Acute effects of cold, heat and contrast pressure therapy on forearm muscles regeneration in combat sports athletes: a randomized clinical trial.

Trybulski R, Kuzdzal A, Stanula A, Muracki J, Kawczynski A, Kuczmik W Sci Rep. 2024; 14(1):22410.

PMID: 39333728 PMC: 11437117. DOI: 10.1038/s41598-024-72412-0.


References
1.
Atkinson G, Nevill A . Selected issues in the design and analysis of sport performance research. J Sports Sci. 2001; 19(10):811-27. DOI: 10.1080/026404101317015447. View

2.
Bizzini M, Mannion A . Reliability of a new, hand-held device for assessing skeletal muscle stiffness. Clin Biomech (Bristol). 2003; 18(5):459-61. DOI: 10.1016/s0268-0033(03)00042-1. View

3.
Williams W . Anatomy of the Knee Joint. J Anat Physiol. 1880; 14(Pt 2):178-84. PMC: 1309929. View

4.
Alamaki A, Hakkinen A, Malkia E, Ylinen J . Muscle tone in different joint positions and at submaximal isometric torque levels. Physiol Meas. 2007; 28(8):793-802. DOI: 10.1088/0967-3334/28/8/003. View

5.
To T, Estrabillo E, Wang C, Cicutto L . Examining intra-rater and inter-rater response agreement: a medical chart abstraction study of a community-based asthma care program. BMC Med Res Methodol. 2008; 8:29. PMC: 2396663. DOI: 10.1186/1471-2288-8-29. View