» Articles » PMID: 31363110

Application of a Limit-Cycle Oscillator Model for Prediction of Circadian Phase in Rotating Night Shift Workers

Overview
Journal Sci Rep
Specialty Science
Date 2019 Aug 1
PMID 31363110
Citations 20
Authors
Affiliations
Soon will be listed here.
Abstract

Practical alternatives to gold-standard measures of circadian timing in shift workers are needed. We assessed the feasibility of applying a limit-cycle oscillator model of the human circadian pacemaker to estimate circadian phase in 25 nursing and medical staff in a field setting during a transition from day/evening shifts (diurnal schedule) to 3-5 consecutive night shifts (night schedule). Ambulatory measurements of light and activity recorded with wrist actigraphs were used as inputs into the model. Model estimations were compared to urinary 6-sulphatoxymelatonin (aMT6s) acrophase measured on the diurnal schedule and last consecutive night shift. The model predicted aMT6s acrophase with an absolute mean error of 0.69 h on the diurnal schedule (SD = 0.94 h, 80% within ±1 hour), and 0.95 h on the night schedule (SD = 1.24 h, 68% within ±1 hour). The aMT6s phase shift from diurnal to night schedule was predicted to within ±1 hour in 56% of individuals. Our findings indicate the model can be generalized to a shift work setting, although prediction of inter-individual variability in circadian phase shift during night shifts was limited. This study provides the basis for further adaptation and validation of models for predicting circadian phase in rotating shift workers.

Citing Articles

Wearables in Chronomedicine and Interpretation of Circadian Health.

Gubin D, Weinert D, Stefani O, Otsuka K, Borisenkov M, Cornelissen G Diagnostics (Basel). 2025; 15(3).

PMID: 39941257 PMC: 11816745. DOI: 10.3390/diagnostics15030327.


SleepSync: Early Testing of a Personalised Sleep-Wake Management Smartphone Application for Improving Sleep and Cognitive Fitness in Defence Shift Workers.

Varma P, Postnova S, Knock S, Howard M, Aidman E, Rajaratnam S Clocks Sleep. 2024; 6(2):267-280.

PMID: 38920420 PMC: 11203003. DOI: 10.3390/clockssleep6020019.


Association of Rest-Activity Rhythm and Risk of Developing Dementia or Mild Cognitive Impairment in the Middle-Aged and Older Population: Prospective Cohort Study.

Haghayegh S, Gao C, Sugg E, Zheng X, Yang H, Saxena R JMIR Public Health Surveill. 2024; 10:e55211.

PMID: 38713911 PMC: 11109857. DOI: 10.2196/55211.


Longitudinal associations of diurnal rest-activity rhythms with fatigue, insomnia, and health-related quality of life in survivors of colorectal cancer up to 5 years post-treatment.

Chong M, Frenken K, Eussen S, Koster A, Pot G, Breukink S Int J Behav Nutr Phys Act. 2024; 21(1):51.

PMID: 38698447 PMC: 11067118. DOI: 10.1186/s12966-024-01601-x.


Mathematical Analysis of Light-sensitivity Related Challenges in Assessment of the Intrinsic Period of the Human Circadian Pacemaker.

Usmani I, Dijk D, Skeldon A J Biol Rhythms. 2024; 39(2):166-182.

PMID: 38317600 PMC: 10996302. DOI: 10.1177/07487304231215844.


References
1.
Rabstein S, Burek K, Lehnert M, Beine A, Vetter C, Harth V . Differences in twenty-four-hour profiles of blue-light exposure between day and night shifts in female medical staff. Sci Total Environ. 2019; 653:1025-1033. DOI: 10.1016/j.scitotenv.2018.10.293. View

2.
Jewett M, Kronauer R, Czeisler C . Phase-amplitude resetting of the human circadian pacemaker via bright light: a further analysis. J Biol Rhythms. 1994; 9(3-4):295-314. DOI: 10.1177/074873049400900310. View

3.
Hansen J, Geving I, Reinertsen R . Adaptation rate of 6-sulfatoxymelatonin and cognitive performance in offshore fleet shift workers: a field study. Int Arch Occup Environ Health. 2010; 83(6):607-15. DOI: 10.1007/s00420-010-0547-x. View

4.
Kronauer R, Forger D, Jewett M . Quantifying human circadian pacemaker response to brief, extended, and repeated light stimuli over the phototopic range. J Biol Rhythms. 2000; 14(6):500-15. DOI: 10.1177/074873099129001073. View

5.
St Hilaire M, Klerman E, Khalsa S, Wright Jr K, Czeisler C, Kronauer R . Addition of a non-photic component to a light-based mathematical model of the human circadian pacemaker. J Theor Biol. 2007; 247(4):583-99. PMC: 3123888. DOI: 10.1016/j.jtbi.2007.04.001. View