Abstract

New mineral trioxide aggregate (MTA) formulations are constantly introduced in the market, usually in a powder-and-liquid form. Bioceramic (Bio-C) Repair is a ready-for-use material suggested as substitute for MTA, but its properties need to be studied. This study evaluated the cytotoxicity, biocompatibility and biomineralization of Bio-C Repair compared to MTA Repair High-Plasticity (MTA-HP) and white MTA-Angelus (MTA-Ang). L929 fibroblasts were exposed to material-extracted (undiluted, ½ and ¼ dilutions; 6, 24 and 48h). Polyethylene tubes with material or empty (control) were implanted in the subcutaneous tissue of rats. After 7 and 30 days (n=8), the specimens were removed for analysis (hematoxylin-eosin, von Kossa and polarized light). Cytotoxicity data were statistically analyzed by two-way ANOVA, and biocompatibility data by Kruskal-Wallis and Dunn tests (p<0.05). The cells exposed to the materials had greater viability at most of the periods compared with control (p<0.05). The undiluted and ½ dilutions of MTA-HP extract showed higher cytocompatibility than Bio-C Repair at 6 h and with the ¼ dilution at 24 h (p<0.05); the white MTA-Ang showed higher cytocompatibility than Bio-C Repair at most of periods (p<0.05). The undiluted white MTA-Ang extract had higher cytocompatibility at 6 and 24h than MTA-HP, and with ½ dilution at 24h (p<0.05). The materials' cytocompatibility was similar at 48h for most dilutions (p>0.05). At 7 and 30 days, the groups had moderate and mild inflammation, respectively (p>0.05). All materials showed positive structures for von Kossa and polarized light. In conclusion, Bio-C Repair had similar cytocompatibility to MTA-based materials is biocompatible and induces biomineralization.

Citing Articles

Comparative evaluation of sealing potential of mineral trioxide aggregate, biodentine, and bio-C repair in furcation perforations: A glucose penetration study.

Shetty A, Sultana H, Srirekha A, Champa C, Pal S, Sahithi V J Conserv Dent Endod. 2025; 28(2):144-149.

PMID: 40046461 PMC: 11878678. DOI: 10.4103/JCDE.JCDE_749_24.


Evaluation of volumetric and surface stability of calcium silicate-based repair cements at different pHs.

Janini A, Alves D, Dos Santos V, Moraes B, da Silva N, Barros-Costa M Clin Oral Investig. 2025; 29(3):160.

PMID: 40000482 DOI: 10.1007/s00784-025-06232-5.


Comparative evaluation of apical microleakage of mineral trioxide aggregate, Biodentine, and Bio-C Repair as root-end filling materials using dye extraction method: An study.

Kunam D, Bode Y, Narra P, Krishna C, Reddy S, Venkateshwarlu M J Conserv Dent Endod. 2025; 27(12):1305-1309.

PMID: 39959012 PMC: 11823578. DOI: 10.4103/JCDE.JCDE_616_24.


Healing the Open Apex: A Case Report on Innovative Apexogenesis of a Maxillary Molar Using Bio-C Repair.

Shetty A, Sultana H, V K, Reddy N Cureus. 2025; 16(12):e76566.

PMID: 39881929 PMC: 11774637. DOI: 10.7759/cureus.76566.


In vivo method to evaluate volumetric changes in bioceramic repair materials.

Ferraz D, Pinto J, Guerreiro-Tanomaru J, Tanomaru-Filho M Braz Dent J. 2024; 35:e245960.

PMID: 39320005 PMC: 11412096. DOI: 10.1590/0103-6440202405960.