» Articles » PMID: 31337107

An EMG Patch for the Real-Time Monitoring of Muscle-Fatigue Conditions During Exercise

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2019 Jul 25
PMID 31337107
Citations 27
Authors
Affiliations
Soon will be listed here.
Abstract

In recent years, wearable monitoring devices have been very popular in the health care field and are being used to avoid sport injuries during exercise. They are usually worn on the wrist, the same as sport watches, or on the chest, like an electrocardiogram patch. Common functions of these wearable devices are that they use real time to display the state of health of the body, and they are all small sized. The electromyogram (EMG) signal is usually used to show muscle activity. Thus, the EMG signal could be used to determine the muscle-fatigue conditions. In this study, the goal is to develop an EMG patch which could be worn on the lower leg, the gastrocnemius muscle, to detect real-time muscle fatigue while exercising. A micro controller unit (MCU) in the EMG patch is part of an ARM Cortex-M4 processor, which is used to measure the median frequency (MF) of an EMG signal in real time. When the muscle starts showing tiredness, the median frequency will shift to a low frequency. In order to delete the noise of the isotonic EMG signal, the EMG patch has to run the empirical mode decomposition algorithm. A two-electrode circuit was designed to measure the EMG signal. The maximum power consumption of the EMG patch was about 39.5 mAh. In order to verify that the real-time MF values measured by the EMG patch were close to the off-line MF values measured by the computer system, we used the root-mean-square value to estimate the difference in the real-time MF values and the off-line MF values. There were 20 participants that rode an exercise bicycle at different speeds. Their EMG signals were recorded with an EMG patch and a physiological measurement system at the same time. Every participant rode the exercise bicycle twice. The averaged root-mean-square values were 2.86 ± 0.86 Hz and 2.56 ± 0.47 Hz for the first and second time, respectively. Moreover, we also developed an application program implemented on a smart phone to display the participants' muscle-fatigue conditions and information while exercising. Therefore, the EMG patch designed in this study could monitor the muscle-fatigue conditions to avoid sport injuries while exercising.

Citing Articles

Effectiveness of Using a Digital Wearable Plantar Pressure Device to Detect Muscle Fatigue: Within-Subject, Repeated Measures Experimental Design.

Chen F, Lin T, Huang Y, Widianawati E JMIR Hum Factors. 2025; 12():e65578.

PMID: 39773695 PMC: 11731697. DOI: 10.2196/65578.


Using a Bodily Weight-Fat Scale for Cuffless Blood Pressure Measurement Based on the Edge Computing System.

Liu S, Wu B, Zhu X, Chin C Sensors (Basel). 2024; 24(23).

PMID: 39686366 PMC: 11645011. DOI: 10.3390/s24237830.


From Tissue to System: What Constitutes an Appropriate Response to Loading?.

Gabbett T, Oetter E Sports Med. 2024; 55(1):17-35.

PMID: 39527327 DOI: 10.1007/s40279-024-02126-w.


Reliability and Convergent Validity of Endurance Indices Derived from Near-Infrared Spectroscopy and Electromyography during a Bilateral Hanging Task in Amateur Rock Climbers.

Kwong W, Li J, Lui C, Luk H, Lau K, Seaby R J Funct Morphol Kinesiol. 2024; 9(3).

PMID: 39311269 PMC: 11417833. DOI: 10.3390/jfmk9030161.


Medical intelligence using PPG signals and hybrid learning at the edge to detect fatigue in physical activities.

Liu P, Song Y, Yang X, Li D, Khosravi M Sci Rep. 2024; 14(1):16149.

PMID: 38997404 PMC: 11245484. DOI: 10.1038/s41598-024-66839-8.


References
1.
Kaikkonen A, Natri A, Pasanen M, Latvala K, Kannus P, Jarvinen M . Isokinetic muscle performance after surgery of the lateral ligaments of the ankle. Int J Sports Med. 1999; 20(3):173-8. DOI: 10.1055/s-2007-971113. View

2.
von Tscharner V . Time-frequency and principal-component methods for the analysis of EMGs recorded during a mildly fatiguing exercise on a cycle ergometer. J Electromyogr Kinesiol. 2002; 12(6):479-92. DOI: 10.1016/s1050-6411(02)00005-6. View

3.
Morris S, Allison G . Effects of abdominal muscle fatigue on anticipatory postural adjustments associated with arm raising. Gait Posture. 2006; 24(3):342-8. DOI: 10.1016/j.gaitpost.2005.10.011. View

4.
Molinari F, Knaflitz M, Bonato P, Actis M . Electrical manifestations of muscle fatigue during concentric and eccentric isokinetic knee flexion-extension movements. IEEE Trans Biomed Eng. 2006; 53(7):1309-16. DOI: 10.1109/TBME.2006.873680. View

5.
Beelen A, Sargeant A . Effect of fatigue on maximal power output at different contraction velocities in humans. J Appl Physiol (1985). 1991; 71(6):2332-7. DOI: 10.1152/jappl.1991.71.6.2332. View