» Articles » PMID: 31304438

Complex Combination of Femoropopliteal Occlusive Disease and Arteriovenous Fistula Treated Using Color-coded Digital Subtraction Angiography

Overview
Date 2019 Jul 16
PMID 31304438
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

Any quantitative assessment of blood flow using conventional angiography remains impossible with current technology. Physicians decide the clinical end point of a procedure by subjective interpretation. Color-coded digital subtraction angiography has been invented to meet this demand and is used primarily in neuroradiology. This report presents the endovascular treatment of a rare complex combination of peripheral artery disease and arteriovenous fistula using guidance of blood flow parameters, such as area under the curve.

Citing Articles

A technique for intra-procedural blood velocity quantitation using time-resolved 2D digital subtraction angiography.

Hoffman C, Periyasamy S, Longhurst C, Medero R, Roldan-Alzate A, Speidel M CVIR Endovasc. 2021; 4(1):11.

PMID: 33411087 PMC: 7790988. DOI: 10.1186/s42155-020-00199-y.

References
1.
Strother C, Bender F, Deuerling-Zheng Y, Royalty K, Pulfer K, Baumgart J . Parametric color coding of digital subtraction angiography. AJNR Am J Neuroradiol. 2010; 31(5):919-24. PMC: 7964185. DOI: 10.3174/ajnr.A2020. View

2.
Lin C, Hung S, Guo W, Chang F, Luo C, Beilner J . Monitoring peri-therapeutic cerebral circulation time: a feasibility study using color-coded quantitative DSA in patients with steno-occlusive arterial disease. AJNR Am J Neuroradiol. 2012; 33(9):1685-90. PMC: 7964755. DOI: 10.3174/ajnr.A3049. View

3.
Struffert T, Ott S, Kowarschik M, Bender F, Adamek E, Engelhorn T . Measurement of quantifiable parameters by time-density curves in the elastase-induced aneurysm model: first results in the comparison of a flow diverter and a conventional aneurysm stent. Eur Radiol. 2012; 23(2):521-7. DOI: 10.1007/s00330-012-2611-2. View

4.
Golitz P, Struffert T, Lucking H, Rosch J, Knossalla F, Ganslandt O . Parametric color coding of digital subtraction angiography in the evaluation of carotid cavernous fistulas. Clin Neuroradiol. 2012; 23(2):113-20. DOI: 10.1007/s00062-012-0184-8. View

5.
Wang J, Cheng J, Huang K, Zhuang Z, Zhang X, Chi J . Quantitative assessment of angiographic perfusion reduction using color-coded digital subtraction angiography during transarterial chemoembolization. Abdom Radiol (NY). 2016; 41(3):545-52. DOI: 10.1007/s00261-015-0622-6. View