» Articles » PMID: 31303757

Stereoelectroencephalography in Epilepsy, Cognitive Neurophysiology, and Psychiatric Disease: Safety, Efficacy, and Place in Therapy

Overview
Publisher Dove Medical Press
Specialty Psychiatry
Date 2019 Jul 16
PMID 31303757
Citations 21
Authors
Affiliations
Soon will be listed here.
Abstract

For patients with drug-resistant epilepsy, surgical intervention may be an effective treatment option if the epileptogenic zone (EZ) can be well localized. Subdural strip and grid electrode (SDE) implantations have long been used as the mainstay of intracranial seizure localization in the United States. Stereoelectroencephalography (SEEG) is an alternative approach in which depth electrodes are placed through percutaneous drill holes to stereotactically defined coordinates in the brain. Long used in certain centers in Europe, SEEG is gaining wider popularity in North America, bolstered by the advent of stereotactic robotic assistance and mounting evidence of safety, without the need for catheter-based angiography. Rates of clinically significant hemorrhage, infection, and other complications appear lower with SEEG than with SDE implants. SEEG also avoids unnecessary craniotomies when seizures are localized to unresectable eloquent cortex, found to be multifocal or nonfocal, or ultimately treated with stereotactic procedures such as laser interstitial thermal therapy (LITT), radiofrequency thermocoagulation (RF-TC), responsive neurostimulation (RNS), or deep brain stimulation (DBS). While SDE allows for excellent localization and functional mapping on the cortical surface, SEEG offers a less invasive option for sampling disparate brain areas, bilateral investigations, and deep or medial targets. SEEG has shown efficacy for seizure localization in the temporal lobe, the insula, lesional and nonlesional extra-temporal epilepsy, hypothalamic hamartomas, periventricular nodular heterotopias, and patients who have had prior craniotomies for resections or grids. SEEG offers a valuable opportunity for cognitive neurophysiology research and may have an important role in the study of dysfunctional networks in psychiatric disease and understanding the effects of neuromodulation.

Citing Articles

Functional segregation of rostral and caudal hippocampus in associative memory.

Vorobiova A, Feurra M, Pavone E, Stieglitz L, Imbach L, Moiseeva V Front Hum Neurosci. 2025; 19:1509163.

PMID: 39996022 PMC: 11848949. DOI: 10.3389/fnhum.2025.1509163.


Trends and hotspots of stereoelectroencephalogram from 2002 to 2023: a bibliometric analysis.

Wang T, Dong H, Li K, Feng T, Yang Y, Chen S Front Neurol. 2025; 15:1464657.

PMID: 39741704 PMC: 11686363. DOI: 10.3389/fneur.2024.1464657.


The surgical interval between robot-assisted SEEG and epilepsy resection surgery is an influencing factor of SSI.

Xie X, Yao H, Zhao H, Liu B, Bai Y, Li H Antimicrob Resist Infect Control. 2024; 13(1):81.

PMID: 39061108 PMC: 11282661. DOI: 10.1186/s13756-024-01438-w.


Origami-inspired soft fluidic actuation for minimally invasive large-area electrocorticography.

Coles L, Ventrella D, Carnicer-Lombarte A, Elmi A, Troughton J, Mariello M Nat Commun. 2024; 15(1):6290.

PMID: 39060241 PMC: 11282215. DOI: 10.1038/s41467-024-50597-2.


Beta-band power modulation in the human amygdala differentiates between go/no-go responses in an arm-reaching task.

Chung R, Martin Del Campo Vera R, Sundaram S, Cavaleri J, Gilbert Z, Leonor A J Neural Eng. 2024; 21(4).

PMID: 38959877 PMC: 11369913. DOI: 10.1088/1741-2552/ad5ebe.


References
1.
Kwan P, Brodie M . Early identification of refractory epilepsy. N Engl J Med. 2000; 342(5):314-9. DOI: 10.1056/NEJM200002033420503. View

2.
Logothetis N, Pauls J, Augath M, Trinath T, Oeltermann A . Neurophysiological investigation of the basis of the fMRI signal. Nature. 2001; 412(6843):150-7. DOI: 10.1038/35084005. View

3.
Guenot M, Isnard J, Ryvlin P, Fischer C, Ostrowsky K, Mauguiere F . Neurophysiological monitoring for epilepsy surgery: the Talairach SEEG method. StereoElectroEncephaloGraphy. Indications, results, complications and therapeutic applications in a series of 100 consecutive cases. Stereotact Funct Neurosurg. 2002; 77(1-4):29-32. DOI: 10.1159/000064595. View

4.
Goto T, Hongo K, Kakizawa Y, Muraoka H, Miyairi Y, Tanaka Y . Clinical application of robotic telemanipulation system in neurosurgery. Case report. J Neurosurg. 2004; 99(6):1082-4. DOI: 10.3171/jns.2003.99.6.1082. View

5.
Kahane P, Ryvlin P, Hoffmann D, Minotti L, Benabid A . From hypothalamic hamartoma to cortex: what can be learnt from depth recordings and stimulation?. Epileptic Disord. 2004; 5(4):205-17. View