Motion Estimation and Correction in Cardiac CT Angiography Images Using Convolutional Neural Networks

Overview
Specialty Radiology
Date 2019 Jul 13
PMID 31299452
Citations 15
Authors
Affiliations
Soon will be listed here.
Abstract

Cardiac motion artifacts frequently reduce the interpretability of coronary computed tomography angiography (CCTA) images and potentially lead to misinterpretations or preclude the diagnosis of coronary artery disease (CAD). In this paper, a novel motion compensation approach dealing with Coronary Motion estimation by Patch Analysis in CT data (CoMPACT) is presented. First, the required data for supervised learning is generated by the Coronary Motion Forward Artifact model for CT data (CoMoFACT) which introduces simulated motion to 19 artifact-free clinical CT cases with step-and-shoot acquisition protocol. Second, convolutional neural networks (CNNs) are trained to estimate underlying 2D motion vectors from 2.5D image patches based on the coronary artifact appearance. In a phantom study with computer-simulated vessels, CNNs predict the motion direction and the motion magnitude with average test accuracies of 13.37°±1.21° and 0.77 ± 0.09 mm, respectively. On clinical data with simulated motion, average test accuracies of 34.85°±2.09° and 1.86 ± 0.11 mm are achieved, whereby the precision of the motion direction prediction increases with the motion magnitude. The trained CNNs are integrated into an iterative motion compensation pipeline which includes distance-weighted motion vector extrapolation. Alternating motion estimation and compensation in twelve clinical cases with real cardiac motion artifacts leads to significantly reduced artifact levels, especially in image data with severe artifacts. In four observer studies, mean artifact levels of 3.08 ± 0.24 without MC and 2.28 ± 0.29 with CoMPACT MC are rated in a five point Likert scale.

Citing Articles

Vessel-targeted compensation of deformable motion in interventional cone-beam CT.

Lu A, Huang H, Hu Y, Zbijewski W, Unberath M, Siewerdsen J Med Image Anal. 2024; 97:103254.

PMID: 38968908 PMC: 11365791. DOI: 10.1016/j.media.2024.103254.


Deformable motion compensation in interventional cone-beam CT with a context-aware learned autofocus metric.

Huang H, Liu Y, Siewerdsen J, Lu A, Hu Y, Zbijewski W Med Phys. 2024; 51(6):4158-4180.

PMID: 38733602 PMC: 11155121. DOI: 10.1002/mp.17125.


Optimizing Coronary Computed Tomography Angiography Using a Novel Deep Learning-Based Algorithm.

Dreesen H, Stroszczynski C, Lell M J Imaging Inform Med. 2024; 37(4):1548-1556.

PMID: 38438697 PMC: 11300758. DOI: 10.1007/s10278-024-01033-w.


Motion artifact correction in cardiac CT using cross-phase temporospatial information and synergistic attention gate and spatial transformer sub-networks.

Gong H, Ahmed Z, Chang S, Koons E, Thorne J, Rajiah P Phys Med Biol. 2024; 69(3).

PMID: 38181426 PMC: 10840999. DOI: 10.1088/1361-6560/ad1b6a.


The influence of motion-compensated reconstruction on coronary artery analysis for a dual-layer detector CT system: a dynamic phantom study.

Dobrolinska M, Tetteroo P, Greuter M, van Hamersvelt R, Prakken N, Slart R Eur Radiol. 2024; 34(8):4874-4882.

PMID: 38175219 DOI: 10.1007/s00330-023-10544-z.