Dose Perturbation by Metallic Biliary Stent in External Beam Radiotherapy of Pancreato-biliary Cancers

Overview
Publisher Springer
Date 2019 Jul 10
PMID 31286454
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

This study aims to investigate dose perturbations caused by a metallic biliary stent (MBS) in patients undergoing external beam radiotherapy for cancers in the pancreato-biliary region. Four MBSs with nitinol mesh were examined in the EasyCube phantom including a custom stent holder fabricated by a 3D printer. For experimental models, three-dimensional conformal radiotherapy plans using a single anterior-posterior (AP) and four-field box (4FB) as well as volumetric modulated arc therapy (VMAT) plan were prepared to deliver the photon beam of 8 Gy to the stent holder. EBT3 film was used to measure dose distributions at four sides surrounding MBS. All MBSs in the AP beam demonstrated mean dose enhancements of 2.3-8.2% at the proximal, left, and right sides. Maximum dose enhancements of 12.3-19.5% appeared at regions surrounding the radiopaque markers. At the location distal to the source, there were mean dose reductions of - 3.6 to - 10.9% and minimum doses of - 11.1 to - 9.5%. The mean and maximum doses with the 4FB plan were in the ranges of - 0.1 to 3.6% and 6.7-14.9%, respectively. The VMAT produced mean doses of - 0.9 to 4.8% and maximum doses of 6.0-15.3%. Dose perturbations were observed with maximum and minimum spots near the stent surface. The use of multiple beams including parallel-opposed pairs reduced dose perturbations caused by the nitinol and radiopaque components within the stent. Special attention is required for patients in whom the radiopaque markers are closely located near critical structures or the target volume.

Citing Articles

A comparison of target volumes drawn on arterial and venous phase scans during radiation therapy planning for patients with pancreatic cancer: the PANCRINJ study.

Zaidi F, Calame P, Chevalier C, Henriques J, Vernerey D, Vuitton L Radiat Oncol. 2024; 19(1):90.

PMID: 39010133 PMC: 11251351. DOI: 10.1186/s13014-024-02477-8.


Dosimetric characteristics of self-expandable metallic and plastic stents for transpapillary biliary decompression in external beam radiotherapy.

Ueda Y, Ikezawa K, Sagawa T, Isono M, Ohira S, Miyazaki M Phys Eng Sci Med. 2024; 47(4):1323-1335.

PMID: 38976186 DOI: 10.1007/s13246-024-01447-4.


Assessment of dose perturbations for metal stent in photon and proton radiotherapy plans for hepatocellular carcinoma.

Lee B, Cho S, Park H, Kang S, Kim J, Chung J Radiat Oncol. 2022; 17(1):125.

PMID: 35842636 PMC: 9288675. DOI: 10.1186/s13014-022-02100-8.


Safety of biliary stent placement followed by definitive chemoradiotherapy in patients with pancreatic cancer with bile duct obstruction.

Hayakawa S, Ito K, Hayakawa J, Murofushi K, Karasawa K J Gastrointest Oncol. 2021; 12(5):2260-2267.

PMID: 34790390 PMC: 8576232. DOI: 10.21037/jgo-21-198.


Patient-Specific Quality Assurance Using a 3D-Printed Chest Phantom for Intraoperative Radiotherapy in Breast Cancer.

Choi Y, Lee I, Park K, Park K, Cho Y, Kim J Front Oncol. 2021; 11:629927.

PMID: 33791216 PMC: 8005710. DOI: 10.3389/fonc.2021.629927.