» Articles » PMID: 31279762

Indoor Hospital Air and the Impact of Ventilation on Bioaerosols: a Systematic Review

Overview
Journal J Hosp Infect
Date 2019 Jul 8
PMID 31279762
Citations 44
Authors
Affiliations
Soon will be listed here.
Abstract

Healthcare-acquired infections (HAIs) continue to persist in hospitals, despite the use of increasingly strict infection-control precautions. Opportunistic airborne transmission of potentially pathogenic bioaerosols may be one possible reason for this persistence. Therefore, this study aimed to systematically review the concentrations and compositions of indoor bioaerosols in different areas within hospitals and the effects of different ventilation systems. Electronic databases (Medline and Web of Science) were searched to identify articles of interest. The search was restricted to articles published from 2000 to 2017 in English. Aggregate data was used to examine the differences in mean colony forming units per cubic metre (cfu/m) between different hospital areas and ventilation types. A total of 36 journal articles met the eligibility criteria. The mean total bioaerosol concentrations in the different areas of the hospitals were highest in the inpatient facilities (77 cfu/m, 95% confidence interval (CI): 55-108) compared with the restricted (13cfu/m, 95% CI: 10-15) and public areas (14 cfu/m, 95% CI: 10-19). Hospital areas with natural ventilation had the highest total bioaerosol concentrations (201 cfu/m, 95% CI: 135-300) compared with areas using conventional mechanical ventilation systems (20 cfu/m, 95% CI: 16-24). Hospital areas using sophisticated mechanical ventilation systems (such as increased air changes per hour, directional flow and filtration systems) had the lowest total bioaerosol concentrations (9 cfu/m, 95% CI: 7-13). Operating sophisticated mechanical ventilation systems in hospitals contributes to improved indoor air quality within hospitals, which assists in reducing the risk of airborne transmission of HAIs.

Citing Articles

Open-set deep learning-enabled single-cell Raman spectroscopy for rapid identification of airborne pathogens in real-world environments.

Zhu L, Yang Y, Xu F, Lu X, Shuai M, An Z Sci Adv. 2025; 11(2):eadp7991.

PMID: 39772685 PMC: 11708874. DOI: 10.1126/sciadv.adp7991.


Assessment of airborne bacteria from a public health institution in Mexico City.

Calderon-Ezquerro M, Ponce de Leon A A, Brunner-Mendoza C, Guerrero-Guerra C C, Sanchez-Flores A, Salinas-Peralta I PLOS Glob Public Health. 2024; 4(11):e0003672.

PMID: 39509382 PMC: 11542838. DOI: 10.1371/journal.pgph.0003672.


Hospital-borne hazardous air pollutants and air cleaning strategies amid the surge of SARS-CoV-2 new variants.

Gupta N, Abd El-Gawaad N, Mallasiy L Heliyon. 2024; 10(20):e38874.

PMID: 39449698 PMC: 11497388. DOI: 10.1016/j.heliyon.2024.e38874.


The relationship between occupant behaviour and indoor air quality in Malaysian hospital outpatient departments: A multistage cross-sectional study.

Ibrahim F, Samsudin E, Ishak A, Sathasivam J Heliyon. 2024; 10(14):e34454.

PMID: 39082032 PMC: 11284367. DOI: 10.1016/j.heliyon.2024.e34454.


Emerging contaminants: A One Health perspective.

Wang F, Xiang L, Leung K, Elsner M, Zhang Y, Guo Y Innovation (Camb). 2024; 5(4):100612.