» Articles » PMID: 31223245

Association Between Titration Method and Outcomes of First Night Satisfaction and CPAP Compliance

Overview
Date 2019 Jun 22
PMID 31223245
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

Introduction: The gold standard therapy for obstructive sleep apnoea syndrome (OSAS) is continuous positive airway pressure (CPAP). Our study evaluated the relationship between first night satisfaction and CPAP compliance, and the effect of using the titration method in this relationship.

Methods: Between January 2012 and December 2012, 40 patients with the diagnosis of OSAS and without comorbidities, who had undergone CPAP titration, were included. Of these, 20 patients had undergone manual titration (MT) with polysomnography, whereas 20 patients had undergone auto-adjusted CPAP (APAP) titration. Questionnaires were administered during the morning of the titration night. The first-year adherence to treatment and patient compliance were evaluated.

Results: Forty patients were randomised in two groups; 35 patients who could procure the CPAP and were available at the end of the first year completed the study. From the 35 patients, 20 (6 males; 40%) were in the MT group while 15 (6 males; 30%) were in the APAP group. No significant difference was detected between the mean titration pressure levels obtained with the MT or APAP group. There was no difference in terms of responses to the questions on the questionnaire between the two groups. At the first-year evaluation, no significant difference was detected between the groups.

Conclusions: The titration method used to detect CPAP pressure, MT, or APAP does not affect patient satisfaction on the day following the titration night, and does not affect first-year compliance.

Citing Articles

Prediction of Optimal Positive Airway Pressure in Chinese Patients With Obstructive Sleep Apnea.

Pang F, Deng W, Huang J, Guo Y, Lin M, Zhang X Clin Respir J. 2024; 18(12):e70047.

PMID: 39716408 PMC: 11666474. DOI: 10.1111/crj.70047.

References
1.
McArdle N, Devereux G, Heidarnejad H, Engleman H, Mackay T, Douglas N . Long-term use of CPAP therapy for sleep apnea/hypopnea syndrome. Am J Respir Crit Care Med. 1999; 159(4 Pt 1):1108-14. DOI: 10.1164/ajrccm.159.4.9807111. View

2.
Janson C, Noges E, Lindberg E . What characterizes patients who are unable to tolerate continuous positive airway pressure (CPAP) treatment?. Respir Med. 2000; 94(2):145-9. DOI: 10.1053/rmed.1999.0703. View

3.
Pelletier-Fleury N, Rakotonanahary D, Fleury B . The age and other factors in the evaluation of compliance with nasal continuous positive airway pressure for obstructive sleep apnea syndrome. A Cox's proportional hazard analysis. Sleep Med. 2001; 2(3):225-232. DOI: 10.1016/s1389-9457(00)00063-0. View

4.
Sin D, Mayers I, Man G, Pawluk L . Long-term compliance rates to continuous positive airway pressure in obstructive sleep apnea: a population-based study. Chest. 2002; 121(2):430-5. DOI: 10.1378/chest.121.2.430. View

5.
Massie C, Hart R . Clinical outcomes related to interface type in patients with obstructive sleep apnea/hypopnea syndrome who are using continuous positive airway pressure. Chest. 2003; 123(4):1112-8. DOI: 10.1378/chest.123.4.1112. View