Potential Role of Abbreviated MRI for Breast Cancer Screening in an Academic Medical Center

Overview
Journal Breast J
Publisher Wiley
Date 2019 Jun 18
PMID 31206889
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

The purpose is to determine whether an abbreviated MRI protocol (ABMR) is ready to be used for breast cancer screening in an academic practice setting. Two hundred and fifty nine breast MRIs from 1/1/2012 to 6/30/2012 were retrospectively reviewed using ABMR (MIP, Pre-contrastT1, single dynamic post-contrastT1, and subtraction). Five breast radiologists (4-28 year-expr) participated in this reader study performed in two phases: Phase1 - radiologist's privy to clinical history but not to comparison imaging. Phase2 - radiologists provided comparison imaging. For phase1, studies were reviewed using three steps: (a) MIP only (positive/negative/intermediate); (b) ABMR (recall/no recall) and (c) With T2 (for changes in recommendations). Radiologist also recorded total time for interpretation. In Phase2 the MRIs coded as "recall" were re-reviewed with available comparison studies, noting changes in final recommendation. The abnormal interpretation rates (AIRs) were calculated for phase1 and phase2 results with comparison to the original full protocol. Of the 259 patients (avg. age-52 years; range 26-78), there were seven cancers (three invasive, three DCIS and one breast lymphoma). Acquisition time for ABMR was 3 minutes, ABMR + T2-8 minutes, and original full protocol 16 minutes. Average MIP was positive or indeterminate in 86% (6/7) and negative in 14% (1/7) cancers. The average AIR for MIP only was 20.8% (sens-77.1%; spec-80.8%. The AIR w/o comparisons was 25.6% (sens-91.4%; spec- 76.2%); however the average AIR decreased in phase 2 with comparisons to 13.7% (sens-91.4%; spec-88.5%). The AIR of the original full protocol read was 16.2% (sens-100%; spec-85.7%). Addition of T2 changed assessment in only 3% (1.2%-6.5%). Avg. read time for ABMR including T2 was 2.5 minutes (1.6-4.0 minutes). ABMR is reliable for breast cancer screening, with acceptable interpretation time and acceptable AIR.

Citing Articles

Diagnostic validity of abbreviated breast MRI in the diagnosis of breast cancer: a comparative study to the full breast MRI protocol using BI-RADS.

Ebaid N, Assy M, Eldin A Pol J Radiol. 2024; 89:e80-e87.

PMID: 38510549 PMC: 10953509. DOI: 10.5114/pjr.2024.135474.


Evaluating the effectiveness of abbreviated breast MRI (abMRI) interpretation training for mammogram readers: a multi-centre study assessing diagnostic performance, using an enriched dataset.

Jones L, Marshall A, Elangovan P, Geach R, McKeown-Keegan S, Vinnicombe S Breast Cancer Res. 2022; 24(1):55.

PMID: 35907862 PMC: 9338668. DOI: 10.1186/s13058-022-01549-5.


Biomimetic nanobubbles for triple-negative breast cancer targeted ultrasound molecular imaging.

Jugniot N, Massoud T, Dahl J, Paulmurugan R J Nanobiotechnology. 2022; 20(1):267.

PMID: 35689262 PMC: 9185914. DOI: 10.1186/s12951-022-01484-9.


MRI Screening of Mutation Carriers: Comparison of Standard Protocol and Abbreviated Protocols With and Without T2-Weighted Images.

Daimiel Naranjo I, Sogani J, Saccarelli C, Horvat J, Sevilimedu V, Hughes M AJR Am J Roentgenol. 2021; 218(5):810-820.

PMID: 34935399 PMC: 9422039. DOI: 10.2214/AJR.21.27022.


Abbreviated magnetic resonance imaging in breast cancer: A systematic review of literature.

Hernandez M, Osorio S, Florez K, Ospino A, Diaz G Eur J Radiol Open. 2020; 8:100307.

PMID: 33364260 PMC: 7750142. DOI: 10.1016/j.ejro.2020.100307.