Atrial Fibrillation Ablation with a Spring Sensor-irrigated Contact Force-sensing Catheter Compared with Other Ablation Catheters: Systematic Literature Review and Meta-analysis

Overview
Journal BMJ Open
Specialty General Medicine
Date 2019 Jun 14
PMID 31189669
Citations 15
Authors
Affiliations
Soon will be listed here.
Abstract

Objectives: The objective of our review was to systematically assess available evidence on the effectiveness, safety and efficiency of a spring sensor-irrigated contact force (CF) catheter (THERMOCOOL SMARTTOUCH Catheter (ST)) for percutaneous ablation of paroxysmal or persistent atrial fibrillation (AF), compared with other ablation catheters, or with the ST with the operator blinded to CF data.

Design: Systematic literature review and meta-analysis.

Background: Emerging evidence suggests improved clinical outcomes of AF ablation using CF-sensing catheters; however, reviews to date have included data from multiple, distinct CF technologies.

Methods: We conducted a systematic review and meta-analysis of published studies comparing the use of ST versus other ablation catheters for the treatment of AF. A comprehensive search of electronic and manual sources was conducted. The primary endpoint was freedom from recurrent atrial tachyarrhythmia (AT) at 12 months. Procedural and safety data were also analysed.

Results: Thirty-four studies enrolling 5004 patients were eligible. The use of ST was associated with increased odds of freedom from AT at 12 months (71.0%vs60.8%; OR 1.454, 95% CI 1.12 to 1.88, p0.004) over the comparator group, and the effect size was most evident in paroxysmal AF patients (75.6%vs64.7%; OR 1.560, 95% CI 1.09 to 2.24, p=0.015). Procedure and fluoroscopy times were shorter with ST (p=0.05 and p<0.01, respectively, vs comparator groups). The reduction in procedure time is estimated at 15.5 min (9.0%), and fluoroscopy time 4.8 min (18.7%). Complication rates, including cardiac tamponade, did not differ between groups.

Conclusions: Compared with the use of other catheters, AF ablation using the CF-sensing ST catheter for AF is associated with improved success rates, shorter procedure and fluoroscopy times and similar safety profile.

Citing Articles

Invasive strategies for rhythm control of atrial fibrillation: a narrative review.

Kim H, Lee C J Yeungnam Med Sci. 2024; 41(4):279-287.

PMID: 39307574 PMC: 11534407. DOI: 10.12701/jyms.2024.00703.


The importance of electrode-tissue proximity in creating pulsed field ablation lesions: insights from a sub-acute preclinical model.

Mehta N, Pinkhas D, Mattison L, Sigg D, Kirchhof N, Patequi A J Interv Card Electrophysiol. 2024; .

PMID: 39150656 DOI: 10.1007/s10840-024-01857-0.


High-power short-duration catheter ablation of atrial fibrillation: is it really a new era? Comparison between new and old radiofrequency contact force-sensing catheters.

Dello Russo A, DAngelo L, Compagnucci P, Cipolletta L, Parisi Q, Valeri Y J Interv Card Electrophysiol. 2023; 67(3):549-557.

PMID: 37584862 DOI: 10.1007/s10840-023-01612-x.


Empirical superior vena cava isolation improves outcomes of radiofrequency re-ablation in pulmonary vein isolation non-responders: A 2-center retrospective study in China.

Gu Z, Yang G, Ju W, Li M, Chen H, Gu K Front Cardiovasc Med. 2022; 9:1049414.

PMID: 36568556 PMC: 9768188. DOI: 10.3389/fcvm.2022.1049414.


Effect of electrophysiological mapping on non-transmural annulus ablation and atrial fibrillation recurrence prediction after 6 months of Cox-Maze IV procedure.

Sun Z, Fan C, Song L, Zhang H, Jiang Z, Tan H Front Cardiovasc Med. 2022; 9:931845.

PMID: 35911537 PMC: 9334885. DOI: 10.3389/fcvm.2022.931845.


References
1.
Reddy V, Pollak S, Lindsay B, McElderry H, Natale A, Kantipudi C . Relationship Between Catheter Stability and 12-Month Success After Pulmonary Vein Isolation: A Subanalysis of the SMART-AF Trial. JACC Clin Electrophysiol. 2018; 2(6):691-699. DOI: 10.1016/j.jacep.2016.07.014. View

2.
Makimoto H, Heeger C, Lin T, Rillig A, Metzner A, Wissner E . Comparison of contact force-guided procedure with non-contact force-guided procedure during left atrial mapping and pulmonary vein isolation: impact of contact force on recurrence of atrial fibrillation. Clin Res Cardiol. 2015; 104(10):861-70. DOI: 10.1007/s00392-015-0855-y. View

3.
Liberati A, Altman D, Tetzlaff J, Mulrow C, Gotzsche P, Ioannidis J . The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate health care interventions: explanation and elaboration. PLoS Med. 2009; 6(7):e1000100. PMC: 2707010. DOI: 10.1371/journal.pmed.1000100. View

4.
Marai I, Suleiman M, Blich M, Lessick J, Abadi S, Boulos M . Impact of computed tomography image and contact force technology on catheter ablation for atrial fibrillation. World J Cardiol. 2016; 8(4):317-22. PMC: 4840165. DOI: 10.4330/wjc.v8.i4.317. View

5.
Conti S, Weerasooriya R, Novak P, Champagne J, Lim H, Macle L . Contact force sensing for ablation of persistent atrial fibrillation: A randomized, multicenter trial. Heart Rhythm. 2017; 15(2):201-208. DOI: 10.1016/j.hrthm.2017.10.010. View