Accuracy and Precision of Non-invasive Cardiac Output Monitoring by Electrical Cardiometry: a Systematic Review and Meta-analysis

Overview
Publisher Springer
Date 2019 Jun 9
PMID 31175501
Citations 26
Authors
Affiliations
Soon will be listed here.
Abstract

Cardiac output monitoring is used in critically ill and high-risk surgical patients. Intermittent pulmonary artery thermodilution and transpulmonary thermodilution, considered the gold standard, are invasive and linked to complications. Therefore, many non-invasive cardiac output devices have been developed and studied. One of those is electrical cardiometry. The results of validation studies are conflicting, which emphasize the need for definitive validation of accuracy and precision. We performed a database search of PubMed, Embase, Web of Science and the Cochrane Library of Clinical Trials to identify studies comparing cardiac output measurement by electrical cardiometry and a reference method. Pooled bias, limits of agreement (LoA) and mean percentage error (MPE) were calculated using a random-effects model. A pooled MPE of less than 30% was considered clinically acceptable. A total of 13 studies in adults (620 patients) and 11 studies in pediatrics (603 patients) were included. For adults, pooled bias was 0.03 L min [95% CI - 0.23; 0.29], LoA - 2.78 to 2.84 L min and MPE 48.0%. For pediatrics, pooled bias was - 0.02 L min [95% CI - 0.09; 0.05], LoA - 1.22 to 1.18 L min and MPE 42.0%. Inter-study heterogeneity was high for both adults (I = 93%, p < 0.0001) and pediatrics (I = 86%, p < 0.0001). Despite the low bias for both adults and pediatrics, the MPE was not clinically acceptable. Electrical cardiometry cannot replace thermodilution and transthoracic echocardiography for the measurement of absolute cardiac output values. Future research should explore it's clinical use and indications.

Citing Articles

Comparison of noninvasive electrical cardiometry and transpulmonary thermodilution for cardiac output measurement in critically ill patients: a prospective observational study.

Song W, Guo J, Cao D, Jiang J, Yang T, Ma X BMC Anesthesiol. 2025; 25(1):123.

PMID: 40082773 PMC: 11905673. DOI: 10.1186/s12871-025-03005-1.


Electrical cardiometry for non-invasive cardiac output monitoring: a method comparison study in patients after coronary artery bypass graft surgery.

Greiwe G, Saad R, Hapfelmeier A, Neumann N, Tariparast P, Saugel B J Clin Monit Comput. 2024; .

PMID: 39661264 DOI: 10.1007/s10877-024-01246-y.


Performance evaluation of non-invasive cardiac output monitoring device (HemoVista) based on multi-channel thoracic impedance plethysmography technology.

Park J, Choi B Acute Crit Care. 2024; 39(4):565-572.

PMID: 39558594 PMC: 11617851. DOI: 10.4266/acc.2024.00731.


Hemodynamic monitoring during weaning from mechanical ventilation in critically ill pediatric patients: a prospective observational study.

Abdelgawad T, Ibrahim H, Elsayed E, Abdelhamid N, Bawady S, Rezk A BMC Pediatr. 2024; 24(1):681.

PMID: 39462317 PMC: 11515244. DOI: 10.1186/s12887-024-05110-5.


Evaluating tissue hypoxia and the response to fluid administration in septic shock patients: a metabolic cluster analysis.

Espinal C, Cortes E, Perez-Madrigal A, Saludes P, Gil A, Caballer A BMC Anesthesiol. 2024; 24(1):273.

PMID: 39103769 PMC: 11299339. DOI: 10.1186/s12871-024-02662-y.


References
1.
Raue W, Swierzy M, Koplin G, Schwenk W . Comparison of electrical velocimetry and transthoracic thermodilution technique for cardiac output assessment in critically ill patients. Eur J Anaesthesiol. 2009; 26(12):1067-71. DOI: 10.1097/EJA.0b013e32832bfd94. View

2.
Tomaske M, Knirsch W, Kretschmar O, Balmer C, Woitzek K, Schmitz A . Evaluation of the Aesculon cardiac output monitor by subxiphoidal Doppler flow measurement in children with congenital heart defects. Eur J Anaesthesiol. 2009; 26(5):412-5. DOI: 10.1097/EJA.0b013e3283240438. View

3.
Boet A, Jourdain G, Demontoux S, De Luca D . Stroke volume and cardiac output evaluation by electrical cardiometry: accuracy and reference nomograms in hemodynamically stable preterm neonates. J Perinatol. 2016; 36(9):748-52. DOI: 10.1038/jp.2016.65. View

4.
Grollmuss O, Demontoux S, Capderou A, Serraf A, Belli E . Electrical velocimetry as a tool for measuring cardiac output in small infants after heart surgery. Intensive Care Med. 2012; 38(6):1032-9. DOI: 10.1007/s00134-012-2530-3. View

5.
Cecconi M, Corredor C, Arulkumaran N, Abuella G, Ball J, Grounds R . Clinical review: Goal-directed therapy-what is the evidence in surgical patients? The effect on different risk groups. Crit Care. 2013; 17(2):209. PMC: 3679445. DOI: 10.1186/cc11823. View