Quantitative 4D-Digital Subtraction Angiography to Assess Changes in Hepatic Arterial Flow During Transarterial Embolization: A Feasibility Study in a Swine Model

Overview
Date 2019 Jun 5
PMID 31160194
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To determine the feasibility of using time-resolved 3D-digital subtraction angiography (4D-DSA) for quantifying changes in hepatic arterial blood flow and velocity during transarterial embolization.

Materials And Methods: Hepatic arteriography and selective transarterial embolization were performed in 4 female domestic swine (mean weight, 54 kg) using 100-300-μm microspheres. Conventional 2D and 4D-DSA were performed before, during, and after each embolization. From the 4D-DSA reconstructions, blood flow and velocity values were calculated for hepatic arterial branches using a pulsatility-based algorithm. 4D-DSA velocity values were compared to those measured using an intravascular Doppler wire with a linear regression analysis. Paired t-tests were used to compare data before and after embolization.

Results: There was a weak-to-moderate but statistically significant correlation of flow velocities measured with 4D-DSA and the Doppler wire (r = 0.35, n = 39, P = .012). For vessels with high pulsatility, the correlation was higher (r = 0.64, n = 11, P = .034), and the relationship between 4D-DSA and the Doppler wire fit a linear model with a positive bias toward the Doppler wire (failed to reject at 95% confidence level, P = .208). 4D-DSA performed after partial embolization showed a reduction in velocity in the embolized hepatic arteries compared to pre-embolization (mean, 3.96 ± 0.74 vs 11.8 2± 2.15 cm/s, P = .006).

Conclusion: Quantitative 4D-DSA can depict changes in hepatic arterial blood velocity during transarterial embolization in a swine model. Further work is needed to optimize 4D-DSA acquisitions and to investigate its applicability in humans.

Citing Articles

Interleaved x-ray imaging: A method for simultaneous acquisition of quantitative and diagnostic digital subtraction angiography.

Whitehead J, Hoffman C, Wagner M, Minesinger G, Nikolau E, Laeseke P Med Phys. 2023; 51(4):2468-2478.

PMID: 37856176 PMC: 10994749. DOI: 10.1002/mp.16794.


Spatiotemporal frequency domain analysis for blood velocity measurement during embolization procedures.

Wagner M, Whitehead J, Periyasamy S, Laeseke P, Speidel M Med Phys. 2023; 51(3):1726-1737.

PMID: 37665770 PMC: 10909916. DOI: 10.1002/mp.16715.


In silico simulation of hepatic arteries: An open-source algorithm for efficient synthetic data generation.

Whitehead J, Laeseke P, Periyasamy S, Speidel M, Wagner M Med Phys. 2023; 50(9):5505-5517.

PMID: 36950870 PMC: 10517083. DOI: 10.1002/mp.16379.


A technique for intra-procedural blood velocity quantitation using time-resolved 2D digital subtraction angiography.

Hoffman C, Periyasamy S, Longhurst C, Medero R, Roldan-Alzate A, Speidel M CVIR Endovasc. 2021; 4(1):11.

PMID: 33411087 PMC: 7790988. DOI: 10.1186/s42155-020-00199-y.


Optimization of quantitative time-resolved 3D (4D) digital subtraction angiography in a porcine liver model.

Meram E, Shaughnessy G, Longhurst C, Hoffman C, Wagner M, Mistretta C Eur Radiol Exp. 2020; 4(1):37.

PMID: 32613472 PMC: 7329977. DOI: 10.1186/s41747-020-00164-3.