Predictors of Successful Ultrasound Guided Femoral Vein Cannulation in Electrophysiological Procedures

Overview
Date 2019 May 30
PMID 31139278
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Vascular complications are frequently reported after electrophysiological (EP) procedures. Ultrasound (US) guidance during femoral vein cannulation has shown to reduce vascular damage related to unsuccessful attempts.The aim of our study is to define, under ultrasound guidance,anatomical and technical predictors of successful femoral vein cannulation in a cohort of patients undergoing EP.

Material And Methods: From December 2015 to January 2018, 192 patients (mean age 63,1±15,9 years, M:F=118:74) undergoing EP were enrolled in the study. US-guided approach to femoral vessels cannulation was used in all subjects by four untrained operators. Femoral vein and artery depths and diameters were measured in all patients. Unsuccessful attempts (UA) and time to successful cannulation (TSC) were also calculated.

Results: Vein and artery depths correlated with body weight (r=0.38 and 0.39, p=0.00), body mass index (r=0.53 and 0.50, p=0.00), and body surface area (r=0.25 and 0.28, p=0.00). Interestingly, the number of UA)positively correlated with vein depth (r=0.23, p=0.01 for the right side and r=0.33, p=0.00 for the left side). Linear regression analysis showed that both vein depth (ß=0.42, p=0.001) andoperator training(ß= -0.75,p=0.00)were independently associated with UA.

Conclusion: Anthropometric features, namely BMI and BSA, may provide information about femoral vein/artery anatomy in patients undergoing EP procedures. Patients with high BMI have deeper and larger veins, however only vein depth is a determinant of successful cannulation. Numbers of UA and TSC significantly decrease with operators training.

Citing Articles

Cryoballoon Pulmonary Vein Isolation in Obese Patients with Atrial Fibrillation Compared to Non-Obese Counterparts: A Meta-Analysis.

Vrachatis D, Papathanasiou K, Kazantzis D, Anagnostopoulos I, Kousta M, Giotaki S Biomedicines. 2025; 13(2).

PMID: 40002711 PMC: 11852532. DOI: 10.3390/biomedicines13020298.


The impact of ultrasound-guided vascular access for catheter ablation of left atrial arrhythmias in a high-volume centre.

Krimphoff A, Urbanek L, Bordignon S, Schaack D, Tohoku S, Chen S J Interv Card Electrophysiol. 2024; 67(5):1247-1255.

PMID: 38573537 PMC: 11289139. DOI: 10.1007/s10840-024-01779-x.


Development of a Modular Tissue Phantom for Evaluating Vascular Access Devices.

Boice E, Berard D, Gonzalez J, Hernandez Torres S, Knowlton Z, Avital G Bioengineering (Basel). 2022; 9(7).

PMID: 35877370 PMC: 9311941. DOI: 10.3390/bioengineering9070319.


AI-Enabled, Ultrasound-Guided Handheld Robotic Device for Femoral Vascular Access.

Brattain L, Pierce T, Gjesteby L, Johnson M, DeLosa N, Werblin J Biosensors (Basel). 2021; 11(12).

PMID: 34940279 PMC: 8699246. DOI: 10.3390/bios11120522.


An In vitro System to Gauge the Thrombolytic Efficacy of Histotripsy and a Lytic Drug.

Bhargava A, Hendley S, Bader K J Vis Exp. 2021; (172).

PMID: 34152319 PMC: 8612092. DOI: 10.3791/62133.


References
1.
Tanaka-Esposito C, Chung M, Abraham J, Cantillon D, Abi-Saleh B, Tchou P . Real-time ultrasound guidance reduces total and major vascular complications in patients undergoing pulmonary vein antral isolation on therapeutic warfarin. J Interv Card Electrophysiol. 2013; 37(2):163-8. PMC: 4081545. DOI: 10.1007/s10840-013-9796-4. View

2.
Calkins H, Willems S, Gerstenfeld E, Verma A, Schilling R, Hohnloser S . Uninterrupted Dabigatran versus Warfarin for Ablation in Atrial Fibrillation. N Engl J Med. 2017; 376(17):1627-1636. DOI: 10.1056/NEJMoa1701005. View

3.
Krothapalli S, Bhave P . My Patient Taking A Novel Oral Anticoagulant Needs Surgery, Device Implantation, Or Ablation. J Atr Fibrillation. 2016; 7(3):1145. PMC: 4956294. DOI: 10.4022/jafib.1145. View

4.
Ackerman T . Research with human subjects. Hastings Cent Rep. 1988; 18(5):47-9. View

5.
Wynn G, Haq I, Hung J, Bonnett L, Lewis G, Webber M . Improving safety in catheter ablation for atrial fibrillation: a prospective study of the use of ultrasound to guide vascular access. J Cardiovasc Electrophysiol. 2014; 25(7):680-5. DOI: 10.1111/jce.12404. View