» Articles » PMID: 31122921

First-Line Sofia Aspiration Thrombectomy Approach Within the Endovascular Treatment of Ischemic Stroke Multicentric Registry: Efficacy, Safety, and Predictive Factors of Success

Overview
Specialty Neurology
Date 2019 May 25
PMID 31122921
Citations 15
Authors
Affiliations
Soon will be listed here.
Abstract

Background And Purpose: After publications on the effectiveness of mechanical thrombectomy by stent retrievers in acute ischemic stroke with large-vessel occlusion, alternative endovascular approaches have been proposed using first-line aspiration catheters. Several devices are currently available to perform A Direct Aspiration First Pass Technique. The Sofia catheter aspiration has been widely used by interventionalists, but data are scarce about its efficacy and safety. Our aim was to report our multicenter thrombectomy experience with first-line Sofia catheter aspiration and to identify independent prognostic factors of clinical and procedural outcomes.

Materials And Methods: We performed a retrospective analysis of the prospectively maintained Endovascular Treatment of Ischemic Stroke multicentric registry. Data from consecutive patients who benefited from thrombectomy with a first-line Sofia approach between January 2013 and April 2018 were studied. We excluded other first-line approaches (stent retriever or combined aspiration and stent retriever) and extracranial occlusions. Baseline characteristics, procedural data, and angiographic and clinical outcomes were analyzed.

Results: During the study period, 296 patients were treated. Mean age and initial NIHSS score were, respectively, 69.5 years and 16. Successful reperfusion, defined by the modified TICI 2b/3, was obtained in 86.1% ( = 255; 95% CI, 81.7%-89.9%). Complete reperfusion (modified TICI 3) was obtained in 41.2% ( = 122; 95% CI, 35.5%-47.1%). A first-pass effect was achieved in 24.2% ( = 71; 95% CI, 19.4%-29.6%). A rescue stent retriever approach was required in 29.7% ( = 88; 95% CI, 24.6%-35.3%). The complication rate was 9.5% ( = 28; 95% CI, 6.4%-13.5%). Forty-three percent ( = 122; 95% CI, 37.1%-48.9%) of patients presented with a favorable 3-month outcome (mRS ≤ 2). Older age, M1-occlusion topography, and intravenous thrombolysis use prior to thrombectomy were independent predictors of the first-pass effect.

Conclusions: The first-line contact aspiration approach appeared safe and efficient with Sofia catheters. These devices achieved very high reperfusion rates with a low requirement for stent retriever rescue therapy, especially for M1 occlusions.

Citing Articles

Safety and effectiveness of SOFIA/SOFIA PLUS for direct aspiration as first line treatment in patients with acute anterior ischemic stroke: results from the prospective, multicentric SESAME study.

Neuberger U, Marnat G, Barreau X, Pitrone A, Caragliano A, Killer-Oberpfalzer M Front Neurol. 2024; 15:1441810.

PMID: 39385819 PMC: 11461265. DOI: 10.3389/fneur.2024.1441810.


Current Approaches and Methods to Understand Acute Ischemic Stroke Treatment Using Aspiration Thrombectomy.

Patki P, Simon S, Costanzo F, Manning K Cardiovasc Eng Technol. 2024; 15(4):481-502.

PMID: 38886306 DOI: 10.1007/s13239-024-00735-0.


Randomized Clinical Trials in Cerebrovascular Neurosurgery From 2018 to 2022.

Kappel A, Nguyen H, Frerichs K, Patel N, Aziz-Sultan M, Du R Cureus. 2024; 16(1):e52397.

PMID: 38361699 PMC: 10869144. DOI: 10.7759/cureus.52397.


A Prospective, Multicenter, Single-Group Target-Value Clinical Trial to Evaluate the Safety and Efficacy of a Large Bore Aspiration Catheter System for the Endovascular Treatment of Acute Ischemic Stroke.

Chen F, Bai X, Hu W, Guo F, Chen J, Zhou Z Front Neurol. 2022; 13:864563.

PMID: 35756925 PMC: 9218266. DOI: 10.3389/fneur.2022.864563.


Efficacy and safety of SOFIA aspiration catheter for mechanical thrombectomy via ADAPT and Solumbra echniques in acute ischemic stroke: A systematic review and meta-analysis.

Essibayi M, Brinjikji W Interv Neuroradiol. 2022; 30(3):326-335.

PMID: 35695222 PMC: 11310730. DOI: 10.1177/15910199221107438.


References
1.
Wong J, Do H, Telischak N, Moraff A, Dodd R, Marks M . Initial experience with SOFIA as an intermediate catheter in mechanical thrombectomy for acute ischemic stroke. J Neurointerv Surg. 2016; 9(11):1103-1106. DOI: 10.1136/neurintsurg-2016-012750. View

2.
Delgado Almandoz J, Kayan Y, Wallace A, Tarrel R, Fease J, Scholz J . Larger ACE 68 aspiration catheter increases first-pass efficacy of ADAPT technique. J Neurointerv Surg. 2018; 11(2):141-146. DOI: 10.1136/neurintsurg-2018-013957. View

3.
Dargazanli C, Fahed R, Blanc R, Gory B, Labreuche J, Duhamel A . Modified Thrombolysis in Cerebral Infarction 2C/Thrombolysis in Cerebral Infarction 3 Reperfusion Should Be the Aim of Mechanical Thrombectomy: Insights From the ASTER Trial (Contact Aspiration Versus Stent Retriever for Successful Revascularization). Stroke. 2018; 49(5):1189-1196. DOI: 10.1161/STROKEAHA.118.020700. View

4.
Schramm P, Navia P, Papa R, Zamarro J, Tomasello A, Weber W . ADAPT technique with ACE68 and ACE64 reperfusion catheters in ischemic stroke treatment: results from the PROMISE study. J Neurointerv Surg. 2018; 11(3):226-231. PMC: 6582710. DOI: 10.1136/neurintsurg-2018-014122. View

5.
Hungerford J, Hyer M, Turk A, Turner R, Chaudry M, Fargen K . Impact of ASPECT scores and infarct distribution on outcomes among patients undergoing thrombectomy for acute ischemic stroke with the ADAPT technique. J Neurointerv Surg. 2016; 9(9):823-829. DOI: 10.1136/neurintsurg-2016-012528. View