First-in-human Experience with Occlusion of the Superior Vena Cava to Reduce Cardiac Filling Pressures in Congestive Heart Failure

Overview
Date 2019 May 22
PMID 31112633
Citations 9
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Acutely decompensated heart failure remains a major clinical problem. Volume overload promotes cardiac and renal dysfunction and is associated with increased morbidity and mortality in heart failure. We hypothesized that transient occlusion of the superior vena cava (SVC) will reduce cardiac filling pressures without reducing cardiac output or systemic blood pressure. The objective of this proof of concept study was to provide initial evidence of safety and feasibility of transient SVC occlusion in patients with acutely decompensated heart failure and reduced ejection fraction.

Methods And Results: In eight patients with systolic heart failure, SVC occlusion was performed using a commercially available occlusion balloon. Five minutes of SVC occlusion reduced biventricular filling pressures without decreasing systemic blood pressure or total cardiac output. In three of the eight patients, a second 10-minutes occlusion had similar hemodynamic effects. SVC occlusion was well-tolerated without development of new symptoms, new neurologic deficits, or any adverse events including stroke, heart attack, or reported SVC injury or thrombosis at 7 days of follow up.

Conclusion: We report the first clinical experience with transient SVC occlusion as a potentially new therapeutic approach to rapidly reduce cardiac filling pressures in heart failure. No prohibitive safety signal was identified and further testing to establish the clinical utility of transient SVC occlusion for acute decompensated heart failure is justified.

Citing Articles

Cardio-Renal Syndrome: Latest Developments in Device-Based Therapy.

Meche V, Kundnani N, Sharma A, Capastraru F, Nistor D, Sarau C J Clin Med. 2025; 13(24.

PMID: 39768738 PMC: 11677936. DOI: 10.3390/jcm13247814.


Device therapies for heart failure with reduced ejection fraction: a new era.

Mody R, Nee Sheth A, Dash D, Mody B, Agrawal A, Monga I Front Cardiovasc Med. 2024; 11:1388232.

PMID: 39494238 PMC: 11527719. DOI: 10.3389/fcvm.2024.1388232.


Emerging Device Therapies for Cardiorenal Syndrome.

Nathan S, Basir M J Soc Cardiovasc Angiogr Interv. 2024; 2(6Part B):101210.

PMID: 39131074 PMC: 11307833. DOI: 10.1016/j.jscai.2023.101210.


Transcatheter interventions for heart failure.

Latib A, Mustehsan M, Abraham W, Jorde U, Bartunek J EuroIntervention. 2023; 18(14):1135-1149.

PMID: 36861266 PMC: 9936253. DOI: 10.4244/EIJ-D-22-00070.


Advances in novel devices for the treatment of heart failure.

Tang R, Chang Y, Song J Heart Fail Rev. 2023; 28(2):331-345.

PMID: 36792818 DOI: 10.1007/s10741-022-10293-z.


References
1.
Holubarsch C, Ruf T, Goldstein D, Ashton R, Nickl W, Pieske B . Existence of the Frank-Starling mechanism in the failing human heart. Investigations on the organ, tissue, and sarcomere levels. Circulation. 1996; 94(4):683-9. DOI: 10.1161/01.cir.94.4.683. View

2.
Vora A, Jones W, DeVore A, Ebner A, Clifton W, Patel M . First-in-human experience with Aortix intraaortic pump. Catheter Cardiovasc Interv. 2018; 93(3):428-433. PMC: 6586004. DOI: 10.1002/ccd.27857. View

3.
Cooper L, Mentz R, Stevens S, Felker G, Lombardi C, Metra M . Hemodynamic Predictors of Heart Failure Morbidity and Mortality: Fluid or Flow?. J Card Fail. 2015; 22(3):182-9. PMC: 4779722. DOI: 10.1016/j.cardfail.2015.11.012. View

4.
Gheorghiade M, Filippatos G, De Luca L, Burnett J . Congestion in acute heart failure syndromes: an essential target of evaluation and treatment. Am J Med. 2006; 119(12 Suppl 1):S3-S10. DOI: 10.1016/j.amjmed.2006.09.011. View

5.
Annamalai S, Esposito M, Reyelt L, Natov P, Jorde L, Karas R . Abdominal Positioning of the Next-Generation Intra-Aortic Fluid Entrainment Pump (Aortix) Improves Cardiac Output in a Swine Model of Heart Failure. Circ Heart Fail. 2018; 11(8):e005115. PMC: 6203333. DOI: 10.1161/CIRCHEARTFAILURE.118.005115. View