Three-Dimensional Echocardiographic Imaging of a Gerbode Defect Complicating Transcatheter Aortic Valve Replacement
Overview
Affiliations
We describe a case of a 77-year-old male who underwent transcatheter aortic valve implantation (TAVR) with Edwards SAPIEN XT size 26 mm for severe aortic stenosis. Postprocedural transesophageal echocardiography (TEE) showed left-to-right shunt between the left ventricular outflow tract just below the bioprosthesis and the right atrium across the atrioventricular septum (Gerbode defect). Three-dimensional echocardiography (3DE) allowed a detailed anatomical imaging of the shape and the location of a small, circular, atrioventricular defect that was a type II, direct, supravalvular, Gerbode-type defect. This is the third report of a Gerbode defect after TAVR whose diagnosis has important implications on clinical decision-making. TEE plays a key role; its diagnostic ability is enriched by the additional value of 3DE.
Winter L, Strizek B, Recker F J Cardiovasc Dev Dis. 2024; 11(6).
PMID: 38921666 PMC: 11203629. DOI: 10.3390/jcdd11060166.
Galzerano D, Kinsara A, Michele S, Vriz O, Fadel B, Musci R Int J Cardiovasc Imaging. 2020; 36(3):403-413.
PMID: 31902093 DOI: 10.1007/s10554-019-01747-x.