» Articles » PMID: 30989274

No Healing Improvement After Rotator Cuff Reconstruction Augmented with an Autologous Periosteal Flap

Overview
Publisher Wiley
Date 2019 Apr 17
PMID 30989274
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To show descriptive clinical and magnetic resonance (MR) imaging results after an additional periosteal flap augmentation in mini-open rotator cuff reconstruction and to evaluate potential healing improvement at long-term follow-up.

Methods: Twenty-three patients with degenerative rotator cuff tears were followed after receiving a mini-open single-row repair with a subtendinous periosteal flap augmentation. Data were collected preoperatively, after 12 months and after 11 years. Clinical examination, simple shoulder test (SST), Constant-Murley Score (CS), ultrasonography examination and 3T MR imaging were performed.

Results: Out of 23 patients, 20 were available for short-term and 19 for final follow-up at a median of 11.5 years (range 10.4-13.0). Questions answered with "yes" in SST improved from baseline 5.0 (range 1.0-8.0) to short 10.5 (range 8.0-12.0) and final follow-up 12.0 (range 7.0-12.0). CS improved from 53.5 (range 25.0-66.0) to 80.8 (range 75.9-89.3) and finally to 79.8 points (range 42.3-95.4). Improvement was highly significant (p < 0.05). Severe retears were found in 9/19 patients. Ossifications along the refixed tendon were noticed in 8/19 cases. Ossifications did not correlate with clinical outcome. At final follow-up, patients with retears seemed likely to have lower strength values in CS (mean ± SD) than patients without retears (7.3 ± 4.1 vs. 12.8 ± 5.3; p < 0.05).

Conclusion: No positive effect on improving healing response in rotator cuff refixation with a periosteal flap augmentation could be found. Retear rate is comparable to that of conventional rotator cuff refixation in the published literature. Ossifications along the tendon, without negatively affecting the clinical outcome, were seen. This invasive technique cannot be advised and should not be used anymore.

Level Of Evidence: IV.

Citing Articles

MiRNAs as Potential Regulators of Enthesis Healing: Findings in a Rodent Injury Model.

Peniche Silva C, De La Vega R, Panos J, Joris V, Evans C, Balmayor E Int J Mol Sci. 2023; 24(10).

PMID: 37239902 PMC: 10218430. DOI: 10.3390/ijms24108556.


A pilot randomised controlled trial assessing standard versus dermal patch-augmented rotator cuff repair found no adverse effects and suggest future trials need a minimum of 150 patients.

Snow M, Kuiper J, James S, Keeling E, Rich S, Amit P Knee Surg Sports Traumatol Arthrosc. 2023; 31(7):2654-2661.

PMID: 36862197 DOI: 10.1007/s00167-023-07356-5.


Enthesis Healing Is Dependent on Scaffold Interphase Morphology-Results from a Rodent Patellar Model.

Peniche Silva C, Muller S, Quirk N, Poh P, Mayer C, Motta A Cells. 2022; 11(11).

PMID: 35681447 PMC: 9179925. DOI: 10.3390/cells11111752.

References
1.
Fuchs B, Weishaupt D, Zanetti M, Hodler J, Gerber C . Fatty degeneration of the muscles of the rotator cuff: assessment by computed tomography versus magnetic resonance imaging. J Shoulder Elbow Surg. 2000; 8(6):599-605. DOI: 10.1016/s1058-2746(99)90097-6. View

2.
Kyung H, Kim S, Oh C, Kim S . Tendon-to-bone tunnel healing in a rabbit model: the effect of periosteum augmentation at the tendon-to-bone interface. Knee Surg Sports Traumatol Arthrosc. 2003; 11(1):9-15. DOI: 10.1007/s00167-002-0317-8. View

3.
Chen C, Chen W, Shih C, Yang C, Liu S, Lin P . Enveloping the tendon graft with periosteum to enhance tendon-bone healing in a bone tunnel: A biomechanical and histologic study in rabbits. Arthroscopy. 2003; 19(3):290-6. DOI: 10.1053/jars.2003.50014. View

4.
BATEMAN J . THE DIAGNOSIS AND TREATMENT OF RUPTURES OF THE ROTATOR CUFF. Surg Clin North Am. 1963; 43:1523-30. DOI: 10.1016/s0039-6109(16)37139-0. View

5.
Youn I, Jones D, Andrews P, Cook M, Suh J . Periosteal augmentation of a tendon graft improves tendon healing in the bone tunnel. Clin Orthop Relat Res. 2004; (419):223-31. DOI: 10.1097/00003086-200402000-00037. View