» Articles » PMID: 30934659

Graphene Oxide Tablets for Sample Preparation of Drugs in Biological Fluids: Determination of Omeprazole in Human Saliva for Liquid Chromatography Tandem Mass Spectrometry

Overview
Journal Molecules
Publisher MDPI
Specialty Biology
Date 2019 Apr 3
PMID 30934659
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

In this study, a novel sort of sample preparation sorbent was developed, by preparing thin layer graphene oxide tablets (GO-Tabs) utilizing a mixture of graphene oxide and polyethylene glycol on a polyethylene substrate. The GO-Tabs were used for extraction and concentration of omeprazole (OME) in human saliva samples. The determination of OME was carried out using liquid chromatography-tandem mass spectrometry (LC⁻MS/MS) under gradient LC conditions and in the positive ion mode (ESI+) with mass transitions of m/z 346.3→198.0 for OME and / 369.98→252.0 for the internal standard. Standard calibration for the saliva samples was in the range of 2.0⁻2000 nmol L. Limits of detection and quantification were 0.05 and 2.0 nmol L, respectively. Method validation showed good method accuracy and precision; the inter-day precision values ranged from 5.7 to 8.3 (%RSD), and the accuracy of determinations varied from -11.8% to 13.3% (% deviation from nominal values). The extraction recovery was 60%, and GO-Tabs could be re-used for more than ten extractions without deterioration in recovery. In this study, the determination of OME in real human saliva samples using GO-Tab extraction was validated.

Citing Articles

Green Bioanalytical Applications of Graphene Oxide for the Extraction of Small Organic Molecules.

Manousi N, Plastiras O, Deliyanni E, Zachariadis G Molecules. 2021; 26(9).

PMID: 34065150 PMC: 8126010. DOI: 10.3390/molecules26092790.

References
1.
Vita M, Abdel-Rehim M, Nilsson C, Hassan Z, Skansen P, Wan H . Stability, pKa and plasma protein binding of roscovitine. J Chromatogr B Analyt Technol Biomed Life Sci. 2005; 821(1):75-80. DOI: 10.1016/j.jchromb.2005.04.014. View

2.
Said R, Kamel M, El-Beqqali A, Abdel-Rehim M . Microextraction by packed sorbent for LC-MS/MS determination of drugs in whole blood samples. Bioanalysis. 2010; 2(2):197-205. DOI: 10.4155/bio.09.187. View

3.
Pfaffe T, Cooper-White J, Beyerlein P, Kostner K, Punyadeera C . Diagnostic potential of saliva: current state and future applications. Clin Chem. 2011; 57(5):675-87. DOI: 10.1373/clinchem.2010.153767. View

4.
Ashri N, Abdel-Rehim M . Sample treatment based on extraction techniques in biological matrices. Bioanalysis. 2011; 3(17):2003-18. DOI: 10.4155/bio.11.201. View

5.
Liu J, Duan Y . Saliva: a potential media for disease diagnostics and monitoring. Oral Oncol. 2012; 48(7):569-77. DOI: 10.1016/j.oraloncology.2012.01.021. View