Abstract

Real-time motion capture of the human arm in the home environment has many usecases, such as video game and therapy applications. The required tracking can be based onoff-the-shelf Inertial Measurement Units (IMUs) with integrated three-axis accelerometers, gyroscopes,and magnetometers. However, this usually requires a homogeneous magnetic field to correctfor orientation drift, which is often not available inside buildings. In this paper, RPMC (RestPose Magnetometer-based drift Correction), a novel method that is robust to long term drift inenvironments with inhomogeneous magnetic fields, is presented. The sensor orientation is estimatedby integrating the angular velocity measured by the gyroscope and correcting drift around the pitchand roll axes with the acceleration information. This commonly leads to short term drift aroundthe gravitational axis. Here, during the calibration phase, the local magnetic field direction for eachsensor, and its orientation relative to the inertial frame, are recorded in a rest pose. It is assumed thatarm movements in free space are exhausting and require regular rest. A set of rules is used to detectwhen the user has returned to the rest pose, to then correct for the drift that has occurred with themagnetometer. Optical validations demonstrated accurate (root mean square error RMS = 6.1), lowlatency (61 ms) tracking of the user's wrist orientation, in real time, for a full hour of arm movements.The reduction in error relative to three alternative methods implemented for comparison was between82.5% and 90.7% for the same movement and environment. Therefore, the proposed arm trackingmethod allows for the correction of orientation drift in an inhomogeneous magnetic field by exploitingthe user's need for frequent rest.

Citing Articles

NONAN GaitPrint: An IMU gait database of healthy older adults.

Wiles T, Kim S, Mangalam M, Sommerfeld J, Brink K, Grunkemeyer A Sci Data. 2025; 12(1):143.

PMID: 39856107 PMC: 11759707. DOI: 10.1038/s41597-024-04359-w.


Systematic review of machine learning applications using nonoptical motion tracking in surgery.

Carciumaru T, Tang C, Farsi M, Bramer W, Dankelman J, Raman C NPJ Digit Med. 2025; 8(1):28.

PMID: 39809851 PMC: 11733004. DOI: 10.1038/s41746-024-01412-1.


MultiSenseBadminton: Wearable Sensor-Based Biomechanical Dataset for Evaluation of Badminton Performance.

Seong M, Kim G, Yeo D, Kang Y, Yang H, DelPreto J Sci Data. 2024; 11(1):343.

PMID: 38580698 PMC: 10997636. DOI: 10.1038/s41597-024-03144-z.


Challenges and solutions for application and wider adoption of wearable robots.

Babic J, Laffranchi M, Tessari F, Verstraten T, Novak D, Sarabon N Wearable Technol. 2024; 2:e14.

PMID: 38486636 PMC: 10936284. DOI: 10.1017/wtc.2021.13.


Adaptive Lifting Index () for Real-Time Instrumental Biomechanical Risk Assessment: Concepts, Mathematics, and First Experimental Results.

Ranavolo A, Ajoudani A, Chini G, Lorenzini M, Varrecchia T Sensors (Basel). 2024; 24(5).

PMID: 38475017 PMC: 10934623. DOI: 10.3390/s24051474.


References
1.
Nussbaum M, Clark L, Lanza M, Rice K . Fatigue and endurance limits during intermittent overhead work. AIHAJ. 2001; 62(4):446-56. DOI: 10.1080/15298660108984646. View

2.
Wu G, van der Helm F, Veeger H, Makhsous M, Van Roy P, Anglin C . ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion--Part II: shoulder, elbow, wrist and hand. J Biomech. 2005; 38(5):981-992. DOI: 10.1016/j.jbiomech.2004.05.042. View

3.
Roetenberg D, Luinge H, Baten C, Veltink P . Compensation of magnetic disturbances improves inertial and magnetic sensing of human body segment orientation. IEEE Trans Neural Syst Rehabil Eng. 2005; 13(3):395-405. DOI: 10.1109/TNSRE.2005.847353. View

4.
Roetenberg D, Slycke P, Veltink P . Ambulatory position and orientation tracking fusing magnetic and inertial sensing. IEEE Trans Biomed Eng. 2007; 54(5):883-90. DOI: 10.1109/TBME.2006.889184. View

5.
Roetenberg D, Baten C, Veltink P . Estimating body segment orientation by applying inertial and magnetic sensing near ferromagnetic materials. IEEE Trans Neural Syst Rehabil Eng. 2007; 15(3):469-71. DOI: 10.1109/TNSRE.2007.903946. View