» Articles » PMID: 30857147

A Proactive Environmental Approach for Preventing Legionellosis in Infants: Water Sampling and Antibiotic Resistance Monitoring, a 3-Years Survey Program

Overview
Specialty Health Services
Date 2019 Mar 13
PMID 30857147
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

A proactive environmental monitoring program was conducted to determine the risk and prevent nosocomial waterborne infections of spp. in infants. Sink taps in a neonatal intensive care unit (NICU) and two obstetric clinics were monitored for spp. A total of 59 water samples were collected during a 3-year period and 20 of them were found colonized with . Standard culture, molecular, and latex agglutination methods were used for the detection and identification of bacteria. Hospital personnel also proceeded with remedial actions (hyperchlorination and thermal shock treatment) in the event of colonization. The minimal inhibitory concentration (MIC) values of erythromycin, ciprofloxacin was determined for isolates using the e-test method. Our data indicate that the majority of neonatal sink-taps were colonized at least once during the study with spp. Among 20 isolates, 5 were considered as low-level resistant, 3 in erythromycin and 2 in ciprofloxacin, while no resistant strains were detected. Environmental surveillance in neonatal and obstetric units is suggested to prevent waterborne infections, and thus to reduce the risk of neonatal nosocomial infections.

Citing Articles

: The Journey from the Environment to the Blood.

Iliadi V, Staykova J, Iliadis S, Konstantinidou I, Sivykh P, Romanidou G J Clin Med. 2022; 11(20).

PMID: 36294446 PMC: 9605555. DOI: 10.3390/jcm11206126.


Lung Ultrasound Monitoring of Legionella Ventilator-Associated Pneumonia in an Extremely Low-Birth-Weight Infant.

Liu J, Qiu R Diagnostics (Basel). 2022; 12(9).

PMID: 36140654 PMC: 9497615. DOI: 10.3390/diagnostics12092253.


Tenets of a holistic approach to drinking water-associated pathogen research, management, and communication.

Proctor C, Garner E, Hamilton K, Ashbolt N, Caverly L, Falkinham 3rd J Water Res. 2022; 211:117997.

PMID: 34999316 PMC: 8821414. DOI: 10.1016/j.watres.2021.117997.


Water as a Source of Antimicrobial Resistance and Healthcare-Associated Infections.

Hayward C, Ross K, Brown M, Whiley H Pathogens. 2020; 9(8).

PMID: 32824770 PMC: 7459458. DOI: 10.3390/pathogens9080667.


Antibiotic Resistance of in Clinical and Water Isolates-A Systematic Review.

Pappa O, Chochlakis D, Sandalakis V, Dioli C, Psaroulaki A, Mavridou A Int J Environ Res Public Health. 2020; 17(16).

PMID: 32796666 PMC: 7459901. DOI: 10.3390/ijerph17165809.

References
1.
Nielsen K, Bangsborg J, Hoiby N . Susceptibility of Legionella species to five antibiotics and development of resistance by exposure to erythromycin, ciprofloxacin, and rifampicin. Diagn Microbiol Infect Dis. 2000; 36(1):43-8. DOI: 10.1016/s0732-8893(99)00095-4. View

2.
Fields B, Benson R, Besser R . Legionella and Legionnaires' disease: 25 years of investigation. Clin Microbiol Rev. 2002; 15(3):506-26. PMC: 118082. DOI: 10.1128/CMR.15.3.506-526.2002. View

3.
Roig J, Rello J . Legionnaires' disease: a rational approach to therapy. J Antimicrob Chemother. 2003; 51(5):1119-29. DOI: 10.1093/jac/dkg191. View

4.
Wullings B, van der Kooij D . Occurrence and genetic diversity of uncultured Legionella spp. in drinking water treated at temperatures below 15 degrees C. Appl Environ Microbiol. 2006; 72(1):157-66. PMC: 1352175. DOI: 10.1128/AEM.72.1.157-166.2006. View

5.
Carratala J, Martin-Herrero J, Mykietiuk A, Garcia-Rey C . Clinical experience in the management of community-acquired pneumonia: lessons from the use of fluoroquinolones. Clin Microbiol Infect. 2006; 12 Suppl 3:2-11. DOI: 10.1111/j.1469-0691.2006.01392.x. View