» Articles » PMID: 3085638

Prediction of the Development of Sigmoid Ischemia on the Day of Aortic Operations. Indirect Measurements of Intramural PH in the Colon

Overview
Journal Arch Surg
Specialty General Surgery
Date 1986 Jun 1
PMID 3085638
Citations 21
Authors
Affiliations
Soon will be listed here.
Abstract

A deviation in an indirect measurement of intramural pH below the limits of normality (6.86) was used as a diagnostic test for sigmoid ischemia in 25 high-risk patients undergoing abdominal aortic operations. The clinical diagnosis of ischemic colitis was made by the attending physicians in only two of the 25, on the day after operation in one and three months after operation in another. In neither was the ischemic colitis considered to have been a causative factor in their subsequent deaths. In contrast, six patients developed pH evidence of ischemia on the day of operation. All six subsequently developed a transient episode of guaiac-positive diarrhea, four developed physical signs consistent with ischemic colitis, and four died. Of 19 who did not develop pH evidence of ischemia, none developed guaiac-positive diarrhea, none developed any signs of ischemic colitis, and none died. Stepwise logistic regression showed the duration of pH evidence of ischemia on the day of operation to be the best predictor for the symptoms and signs of ischemic colitis and for death after operation.

Citing Articles

Sigmoid Volvulus with Widespread Bowel Ischemia after Endoscopic Reduction Successfully Treated with Elective Laparoscopic Surgery.

Yasuda K, Oura S, Kashu N, Yoshitake H, Takami T, Shintani H Case Rep Gastroenterol. 2020; 14(2):286-290.

PMID: 32518540 PMC: 7265717. DOI: 10.1159/000507611.


Transcutaneous CO tension measurement as an indicator of severity of hemorrhagic shock.

Yoshioka M J Anesth. 2017; 10(4):264-268.

PMID: 28921089 DOI: 10.1007/BF02483393.


The impact of endovascular repair of ruptured abdominal aortic aneurysm on the gastrointestinal and renal function.

Makar R, Badger S, ODonnell M, Soong C, Lau L, Young I Int J Vasc Med. 2014; 2014:178323.

PMID: 24616809 PMC: 3927867. DOI: 10.1155/2014/178323.


Rectal luminal Pr(CO2), measured by automated air tonometry, does not reflect gastric luminal Pr(CO2) in children.

Weiss M, Schmitz A, Salgo B, Dullenkopf A J Anesth. 2006; 20(3):243-6.

PMID: 16897250 DOI: 10.1007/s00540-006-0410-0.


Tissue capnometry: does the answer lie under the tongue?.

Maciel A, Creteur J, Vincent J Intensive Care Med. 2005; 30(12):2157-65.

PMID: 15650865 DOI: 10.1007/s00134-004-2416-0.