» Articles » PMID: 30836251

Selective Determination of Sartan Drugs in Environmental Water Samples by Mixed-mode Solid-phase Extraction and Liquid Chromatography Tandem Mass Spectrometry

Overview
Journal Chemosphere
Date 2019 Mar 6
PMID 30836251
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

Herein, a method for the simultaneous determination of the currently prescribed sartan drugs (eprosartan, EPR; olmesartan, OLM; losartan, LOS; candesartan, CAN; telmisartan, TEL; irbesartan, IRB; and valsartan, VAL), and the biodegradation product valsartan acid (VALA), in water samples (raw and treated wastewater, river and tap water) was developed. Solid-phase extraction (SPE) and ultra-performance liquid chromatography (UPLC) tandem mass spectrometry (MS/MS) were employed as concentration and determination techniques, respectively. Different sorbents and elution solvents were tested for sample preparation. Under optimized conditions, samples at neutral pH (6-8 units) were concentrated using mixed-mode (reversed-phase and anionic exchange) cartridges. Thereafter, the sorbent was washed with 5 mL of a methanol: water (1:1) solution, dried under a nitrogen stream and compounds were eluted with 2 mL of methanol: NH (98:2). The accuracy of the method (accounting for SPE efficiency and matrix effects during electrospray ionization) was investigated using solvent-based calibration standards. Global recoveries, obtained for different water matrices (tap, river, treated and raw wastewater), ranged from 82% to 134%, with standard deviations between 2 and 18%. LOQs varied from 2 to 50 ng L. Analysis of un-spiked samples confirmed: (1) the incomplete removal of sartans at sewage treatment plants (STPs), (2) the formation of VALA during municipal water treatment, and (3) the presence of VALA in the processed tap water samples. Additional findings of the current study are the detection of hydroxylated derivatives of the sartan drugs IRB and LOS in wastewater, and the E-Z isomerization of EPR in environmental water samples.

Citing Articles

Calibration of a Tube Passive Sampler in Wastewater Effluent with Adjustable Volumetric Flow for the Assessment of Micropollutants with Fluctuating Concentrations.

Hensel T, Hein J, Reemtsma T, Sperlich A, Gnirss R, Zietzschmann F ACS ES T Water. 2024; 4(12):5310-5319.

PMID: 39698552 PMC: 11651299. DOI: 10.1021/acsestwater.4c00348.


Solid-phase extraction and fractionation of multiclass pollutants from wastewater followed by liquid chromatography tandem-mass spectrometry analysis.

Fernandez-Fernandez V, Ramil M, Cela R, Rodriguez I Anal Bioanal Chem. 2022; 414(14):4149-4165.

PMID: 35461386 PMC: 9124662. DOI: 10.1007/s00216-022-04066-8.


Feature-based molecular networking for identification of organic micropollutants including metabolites by non-target analysis applied to riverbank filtration.

Oberleitner D, Schmid R, Schulz W, Bergmann A, Achten C Anal Bioanal Chem. 2021; 413(21):5291-5300.

PMID: 34286355 PMC: 8405475. DOI: 10.1007/s00216-021-03500-7.


An Ultraperformance Liquid Chromatography Tandem-Mass Spectrometry Method for Determination of Multiclass Pharmaceuticals in Water Sample by Dispersive Liquid-Liquid Microextraction Combined with Ultrasound Assisted Reverse Extraction from....

Iqbal M, Ezzeldin E, Haq N, Alam P ACS Omega. 2021; 6(11):7524-7532.

PMID: 33778264 PMC: 7992067. DOI: 10.1021/acsomega.0c06047.


Integrative analysis of the microbiome and metabolome in understanding the causes of sugarcane bitterness.

Huang W, Sun D, Chen L, An Y Sci Rep. 2021; 11(1):6024.

PMID: 33727648 PMC: 7966368. DOI: 10.1038/s41598-021-85433-w.