» Articles » PMID: 30822791

A Cam-Post Mechanism Is No Longer Necessary in Modern Primary Total Knee Arthroplasty

Overview
Journal J Knee Surg
Date 2019 Mar 2
PMID 30822791
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Conclusive evidence supporting a clinical difference between posterior-stabilized (PS) and cruciate-retaining (CR) designs in total knee arthroplasty (TKA) does not currently exist, despite both designs being used for decades. Proponents of PS designs that employ a cam-and-post mechanism cite in vivo fluoroscopic data that demonstrate improved posterior rollback; however, optimal rollback has never been correlated to superior clinical outcomes. Recently, anterior-lipped and more conforming CR bearings, such as ultracongruent, medial pivot, and dual-pivot designs, have been used to substitute for the posterior cruciate ligament and obviate the need for the cam-post mechanism of a traditional PS design. Advantages of avoiding a PS TKA include eliminating the risk of box cut induced femoral condylar fracture, improving operative efficiency by removing procedural steps, removing the articulation that is a source of wear, postdeformation, breakage, or dislocation, and eliminating patellar clunk. Health care reform efforts mandate cost reduction, and procedural efficiencies and minimizing inventory through the removal of unnecessary bearing options foster that initiative.

Citing Articles

A Comparison of Medial-congruent, Ultracongruent, and Cruciate-retaining Bearings Using a Single Cruciate-retaining Total Knee Design.

Strait A, Wilson E, Ho H, Fricka K, Sershon R Arthroplast Today. 2025; 32:101632.

PMID: 40018089 PMC: 11867298. DOI: 10.1016/j.artd.2025.101632.


No difference in patient-reported outcomes or range of motion between ultracongruent and posterior stabilized total knee arthroplasty: A randomized controlled trial.

Macedo F, Lucas J, Cunha P, Rocha M, Cerqueira R, Basto T J Exp Orthop. 2024; 11(4):e70043.

PMID: 39435297 PMC: 11491980. DOI: 10.1002/jeo2.70043.


Larger Medial Contact Area and More Anterior Contact Position in Medial-Pivot than Posterior-Stabilized Total Knee Arthroplasty during In-Vivo Lunge Activity.

Zou D, Tan J, Zheng N, Ling Z, Yu W, Liow M Bioengineering (Basel). 2023; 10(3).

PMID: 36978681 PMC: 10045283. DOI: 10.3390/bioengineering10030290.


A prospective comparison of total knee arthroplasty using ultra-congruent, condylar-stabilizing, and posterior-stabilized devices implanted with kinematic alignment: better 2-year outcomes with ultra-congruent.

Carlson B, Jones B, Scott D Knee Surg Sports Traumatol Arthrosc. 2022; 31(3):1026-1033.

PMID: 36318322 PMC: 9957877. DOI: 10.1007/s00167-022-07206-w.


Comparison of Kinematics and Contact Mechanics in Normal Knee and Total Knee Replacements: A Computational Investigation.

Shu L, Sato T, Hua X, Sugita N Ann Biomed Eng. 2021; 49(9):2491-2502.

PMID: 34142278 DOI: 10.1007/s10439-021-02812-0.