» Articles » PMID: 30822564

Zerovalent Iron-sand Filtration Can Reduce the Concentration of Multiple Antimicrobials in Conventionally Treated Reclaimed Water

Overview
Journal Environ Res
Publisher Elsevier
Date 2019 Mar 2
PMID 30822564
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

Irrigation with reclaimed water is increasing in areas that lack access to, and infrastructure for, high-level treatment and distribution. Antimicrobial residues are known to persist in conventionally treated reclaimed water, necessitating the investigation of reuse site-based mitigation options to further reduce these contaminants. We examined the effectiveness of a 50:50 volume/volume, particle matched, micro-scale zerovalent iron (ZVI)-sand filter in reducing concentrations of mixtures of antimicrobials present in pH-unadjusted conventionally treated reclaimed water. Twelve antimicrobials (azithromycin, ciprofloxacin, erythromycin, linezolid, oxacillin, oxolinic acid, penicillin G, pipemidic acid, sulfamethoxazole, triclocarban, tetracycline and vancomycin) were quantified using high performance-liquid chromatography-tandem mass spectrometry in reclaimed water, and ZVI-sand filtered reclaimed water, in a two-month long greenhouse-based experiment. Data were analyzed using a non-parametric rank-based approach. ZVI-sand filtration significantly reduced concentrations of azithromycin, ciprofloxacin, oxolinic acid, penicillin G, sulfamethoxazole, linezolid, pipemidic acid and vancomycin. Azithromycin, the antimicrobial with the highest median concentration (320 ng/L), was reduced to below the limit of detection after ZVI-sand filtration. Inorganic element (antimony, beryllium, cadmium, chromium, iron, lead, selenium and thallium) and water quality (free and total chlorine, nitrates, nitrites, pH and total dissolved solids) analyses showed that ZVI-sand filtered reclaimed water quality (nitrate, salinity, and inorganic elements) met the recommended guidelines for agricultural irrigation with reclaimed water. Based on our initial results, ZVI-sand filtration may be a promising basis for a point-of-use filtration system for reclaimed water irrigation on small-scale farms.

Citing Articles

Zero-Valent Iron and Sand Filtration Reduces Levels of Surrogates, and , in Water.

Gutierrez A, Tucker M, Yeager C, Fournet V, Jenkins M, Dubey J Microorganisms. 2024; 12(11).

PMID: 39597733 PMC: 11596780. DOI: 10.3390/microorganisms12112344.


"Zooming" Our Way through Virtual Undergraduate Research Training: A Successful Redesign of the CONSERVE Summer Internship Program.

Malayil L, Negahban-Azar M, Rosenberg Goldstein R, Sharma M, Gleason J, Muise A J Microbiol Biol Educ. 2021; 22(1).

PMID: 33953822 PMC: 8060145. DOI: 10.1128/jmbe.v22i1.2625.


Zero-valent iron sand filtration reduces concentrations of virus-like particles and modifies virome community composition in reclaimed water used for agricultural irrigation.

Chopyk J, Kulkarni P, Nasko D, Bradshaw R, Kniel K, Chiu P BMC Res Notes. 2019; 12(1):223.

PMID: 30975220 PMC: 6458639. DOI: 10.1186/s13104-019-4251-y.