» Articles » PMID: 30819934

Binodal, Wireless Epidermal Electronic Systems with In-sensor Analytics for Neonatal Intensive Care

Abstract

Existing vital sign monitoring systems in the neonatal intensive care unit (NICU) require multiple wires connected to rigid sensors with strongly adherent interfaces to the skin. We introduce a pair of ultrathin, soft, skin-like electronic devices whose coordinated, wireless operation reproduces the functionality of these traditional technologies but bypasses their intrinsic limitations. The enabling advances in engineering science include designs that support wireless, battery-free operation; real-time, in-sensor data analytics; time-synchronized, continuous data streaming; soft mechanics and gentle adhesive interfaces to the skin; and compatibility with visual inspection and with medical imaging techniques used in the NICU. Preliminary studies on neonates admitted to operating NICUs demonstrate performance comparable to the most advanced clinical-standard monitoring systems.

Citing Articles

A method for blood pressure hydrostatic pressure correction using wearable inertial sensors and deep learning.

Colburn D, Chern T, Guo V, Salamat K, Pugliese D, Bradley C NPJ Biosens. 2025; 2(1):5.

PMID: 39897702 PMC: 11785522. DOI: 10.1038/s44328-024-00021-y.


A Design Review for Biomedical Wireless Power Transfer Systems with a Three-Coil Inductive Link through a Case Study for NICU Applications.

Marangalou A, Gonzalez M, Reppucci N, Guler U Electronics (Basel). 2025; 13(19.

PMID: 39839125 PMC: 11748024. DOI: 10.3390/electronics13193947.


3D printable and myoelectrically sensitive hydrogel for smart prosthetic hand control.

Lai J, Xiao L, Zhu B, Xie L, Jiang H Microsyst Nanoeng. 2025; 11(1):15.

PMID: 39833177 PMC: 11747008. DOI: 10.1038/s41378-024-00825-y.


3D active-matrix multimodal sensor arrays for independent detection of pressure and temperature.

Jo Y, Lee Y, Kwon J, Kim S, Ryu G, Yun S Sci Adv. 2025; 11(3):eads4516.

PMID: 39823340 PMC: 11740967. DOI: 10.1126/sciadv.ads4516.


An intelligent hybrid-fabric wristband system enabled by thermal encapsulation for ergonomic human-machine interaction.

Cheng A, Li X, Li D, Chen Z, Cui T, Tao L Nat Commun. 2025; 16(1):591.

PMID: 39799116 PMC: 11724971. DOI: 10.1038/s41467-024-55649-1.


References
1.
Chen W, Kobayashi T, Ichikawa S, Takeuchi Y, Togawa T . Continuous estimation of systolic blood pressure using the pulse arrival time and intermittent calibration. Med Biol Eng Comput. 2000; 38(5):569-74. DOI: 10.1007/BF02345755. View

2.
Baserga M, Puri A, Sola A . The use of topical nitroglycerin ointment to treat peripheral tissue ischemia secondary to arterial line complications in neonates. J Perinatol. 2002; 22(5):416-9. DOI: 10.1038/sj.jp.7210713. View

3.
McLane K, Bookout K, McCord S, McCain J, Jefferson L . The 2003 national pediatric pressure ulcer and skin breakdown prevalence survey: a multisite study. J Wound Ostomy Continence Nurs. 2005; 31(4):168-78. DOI: 10.1097/00152192-200407000-00004. View

4.
Ahlstrom C, Johansson A, Uhlin F, Lanne T, Ask P . Noninvasive investigation of blood pressure changes using the pulse wave transit time: a novel approach in the monitoring of hemodialysis patients. J Artif Organs. 2005; 8(3):192-7. DOI: 10.1007/s10047-005-0301-4. View

5.
Kim J, Chee Y, Park J, Choi J, Park K . A new approach for non-intrusive monitoring of blood pressure on a toilet seat. Physiol Meas. 2006; 27(2):203-11. DOI: 10.1088/0967-3334/27/2/010. View